Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor Leave unplugged overnight Remove vent grille by removing the 2 philips screws Remove the LED panel by removing 1 phillips screw Disconnect all connectors that plug into back of the LED board completely Remove the wires from the switches (3) at the inside edge of the microwave door Gently remove each switch housing and test all three switches for continuity Carefully replace non-functioning switches and reassemble the panel GOOD LUCK
-unplug -remove top and front covers -unplug wire connectors from heating assembly -remove heating assembly from metal stand and push out of the way -remove metal stand from dry -pull out heating assembly -install new one in reserve order
Holder bracket broken so Door swithch could not be activated
Part arrived next day! Thank you Parts Select. Holder bracket on older GE microwave was broken so MW would not start because door latch did not activate door switch. Removed front panel unplugged all the wiring (after I had taken a picture) to gain access to the holder bracket. Unplugged the three door switches. Removed two screws that held the holder bracket. Installed three new door switches into the new holder bracket. Positioned the bracket behind the frame and screwed back in the two screws. Snapped in this seven wire attachments, set the control panel back in the microwave and secured it with two screws. I only needed one screwdriver and one needle nose plier to remove the wire attachment from a door switch which made it easier to remove. 40 minutes.
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
The Halogen Light Bulbs for lighting the area below the microwave seemed to be burned out. I order new bulbs but by the time they arrived the old bulbs appeared to be working again. Not sure why this happened but I have new bulbs if they become burned out for good at some point.
I did some research and found the part through this website. Very easy to change the heater sheath, just took long to take everything apart. Looked at some diagrams to see exactly where the part was.
Ridiculously easy, unscrew, and change bulbs. Having the correct bulbs made all the difference, I did not have to waste time looking for the correct one.