This part fixes the following symptoms:
Won’t turn on
This part works with the following products:
Microwave.
This part works with the following products:
General Electric, Hotpoint.
Part# WB02X32720 replaces these:
WB02X21788, WB06X10256, WB06X10857
Questions and Answers
Be the first to ask our experts a question about this part!
✖
Ask a Question
Ask our experts a question on this part and we'll respond as soon as we can.
Something went wrong. Please try again later.
Your Question Has Been Submitted!
Our experts will send you an email as soon as your question has been answered.
Customer Repair Stories
Average Repair Rating: 2.7 / 5.0, 5 reviews.
What's this?
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
When door was opened, the microwave would turn on.
Looked on line and found a you tube that said to check the door micro switches (there are three of them. Found one of the switches had an actuator that was stuck down. I got the actuator working but problem was still present. Another you tube showed how to repair the contacts in the switch and that solved the problem. however the plastic piece that holds the switches was broken and would not hold the switches securely. Ordered that piece and a new switch. Remove the vent plate on top (one phillips) and the control panel (one phillips). The switch holder is held in place with 2 phillips and is a little tricky to get it out and undo the wires. Once out, it's just a matter of putting the switches into the new holder and reinstalling it. Google the model number and the problem and there's virtually a you tube to repair ANYTHING.
-
David from HILTON HEAD, SC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The power was on but the Microwave would not start.
This is an above the range microwave, use 2 people to remove it. I set it on a table and removed the outer cabinet. I then used jumper leads to discharge the capacitor. I removed the control panel (taking a picture to ensure proper wiring on assembly), then I removed the latch board. Once I had the latch board out I removed the monitor switch (which is the middle switch) and tested it for continuity. This is a normally closed switch. I tested the other two switches as well and found these (normally open) switches for continuity to be good and the monitor switch to have a short. This switch should show continuity when the door is open and should show no resistance when the door is closed. (Take care removing the switches) After I received the parts I installed them in the new Locker Holder and installed the latch board (ensure to follow the latch board adjustment steps located in the control board). I then attached the wiring to the control board and then plugged in the unit. I tested the unit to ensure it functioned correctly. I then installed the outer cabinet, and then installed the unit above the range (Use 2 people for this process). Overall an easy fix you just need to ensure you follow safety procedures (especially when dealing with capacitors.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Take a lot of pictures of the wiring and of the components and take care with the latch board or you'll have to buy a new one when all you really needed is a monitor switch.
Other Parts Used:
-
William from KINGMAN, AZ
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave fan would come on when the door was opened and light would turn on. Determine that the Main Interlock Switch had gone bad.
Replaced all 3 switches and Holder for all 3 switches. All is working great now.
-
Daniel from HOLMEN, WI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Holder bracket broken so Door swithch could not be activated
Part arrived next day! Thank you Parts Select. Holder bracket on older GE microwave was broken so MW would not start because door latch did not activate door switch. Removed front panel unplugged all the wiring (after I had taken a picture) to gain access to the holder bracket. Unplugged the three door switches. Removed two screws that held the holder bracket. Installed three new door switches into the new holder bracket. Positioned the bracket behind the frame and screwed back in the two screws. Snapped in this seven wire attachments, set the control panel back in the microwave and secured it with two screws. I only needed one screwdriver and one needle nose plier to remove the wire attachment from a door switch which made it easier to remove. 40 minutes.
-
David from MISSION VIEJO, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Received damaged parts
The first holder locker was shipped in a soft envelope and was damaged in shipping. I ordered a second holder locker with instructions to ship in a hard container and mentioned what happened to the first holder locker. The second holder locker was shipped also in a soft envelope and was received damaged.
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
I notified customer service and have yet to receive a response.
I now have the part on order with a local company.
Kenneth Files
(831) 688-0740
-
Kenneth from APTOS, CA
-
Difficulty Level:Very Difficult
-
Total Repair Time:30 - 60 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer Reviews
Filter By Rating:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
William G - December 18, 2021

Worked great
Great delivery. Right part. Takes some time and care, but not really really hard. (A lot of wire harnesses to disconnect and keep track of. Take photos)
Kenneth F - July 28, 2020

Part damaged in shipping
First part damaged in shipping. Second part also received damaged. Parts were shipped in a soft mailing envelope, even after my advice when ordering the second time to ship in a hard container.
I am waiting for the part from a local vendor.
Richard Q - September 13, 2018

Just like the original which I broke taking out a switch
Quick delivery, as advertised
Model Cross Reference
This part works with the following models:
PartSelect Number: PS12709820
Manufacturer Part Number: WB02X32720
Manufacturer Part Number: WB02X32720
Brand
Model Number
Description