freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
Very easy to install. Simply follow the hoses to the end. One ends under the freezer door in front. The other requires you to take the back panel off the fridge - then its right there. There is a blue valve where it connects. Pull back on the white ring at the top of the blue valve and the old tube will release. Then you can just pull the old water tank out and thread the new tubes through. Connect the same way and you disconnected.
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
I watched the "how-to" video on the website and decided that I needed to disassemble the icemaker first (before ordering parts) so that I could make sure I was ordering all the parts necessary for a complete repair. Good thing I did. I didn't notice the cracked cover and chipped nut until I had the icemaker all apart. I then ordered the necessary parts. When they arrived 2 days later, I set up a table near my computer so I could re-assemble the unit as I watched the repair video...pausing the video as necessary. It all went without a hitch and worked perfectly when re-installed in the freezer. **Note: I left the old parts out of the ice bucket while I was waiting for the new ones to arrive...taped up the gaping holes in the ice bucket with blue painter's masking tape and re-installed the bucket in the freezer with the icemaker on...so I could still manually retrieve ice out of the bucket. I left the switch on the front of the freezer door in the "water" position to remind me that I couldn't dispense ice. Water dispensing worked fine. The video is the key. Impossible to make a mistake if you pay attention.
Read your instructions, which were very helpful, and followed them to install. It took a while for me to realize that the threaded cap at the end of the auger was a left-hand thread. Other than that, I had no problems.
Refrigerator side gets colder than set temperature. Plastic damper door broken in Fresh Food Air Inlet.
There were not detailed instructions provided with the parts, however, it was fairly simple to determine how to remove the old part. First, I removed all the shelves. Then I took out four screws holding the top light cover. The plasic around the back center column was removed with a pannel tool. The plastic around the water filter was also removed. The old Fresh Food Air Inlet was then able to come out. Remove the connector. Reinstall per instructions provided. Install the other parts in order they were removed.
removed the depenser or ice collecter disassyble,replace the new auger and install the collecter tray in freezer.the bulbs i got was for use as i needed,at a later date i have not been able to fine the ice and water depenser bulbs on the open market.
Auger asm had broken off part of blade at end of auger and would not rotate ice out of dispencer.
Removed 3 screws from end of ice storage box,then removed auger asm.Removed c clip on end with flat screwdriver, then disasembled ice crusher blades and nylon/plastic washers.Carefully staging them for reassembly in the correct way.Use pliers to reinstall c clip after new auger is installed
shut off water supply to unit, pull the unit out,unplug, unscrew lower back cover, locate valve relay unit (bottom left, black and clear hose coming out of it) undo the quick connect for the clear water hose on the right (black one is for ice).
front of the unit, bottom left, locate the other hose (longer one) running to the freezer door from under the unit, undo quick connect.
Inside unit, remove middle drawers, careful with the glass panels as these just lay on top and are not fixed.
undo the 3 screws for the old tank, pull it out, snake the hoses thru the grommet on the bottom, reverse process...all set!