Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Icemaker stripper arm tine broke off (by me), causing ice to remain and not discharge normally. The cause was a stripperarm tine becoming caught under an opposing tine in the icemaker preventing it from discharging ice altogether.
Installed the new stripper arm per instructions - an easy installation. After a few cycles the original problem happened again, the stripper arm tine caught under an opposing tine stopping the unit from operating. I removed the stripper arm, after marking where it was caught, and filed it down so it wouldn't catch anymore. Icemaker works fine now. Troubleshooting tip. If a stripper arm tine is caught under an opposing tine, gently slide a screwdriver between them to release it without breaking the tine. Remove the arm, file it down 1-3 mm, and reinstall.
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Once I got the correct part, (the expanded view of the icemaker is confusing as it shows the partition at the back of the diagram) I removed the ice dispenser from the tub by removing the screws and disengage the tabs holding the dispenser assembly in the tub. The most difficult step was getting the disenser disengaged from the tub. I used two kitchen knives to wedge between the walls of the tub. It was then easy to remove and replace the broken inside partition and reassemble the dispenser. Works like new.
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws. Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website. Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK. I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on. It has been working just fine since then.. In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap Fan was sqeeling
First I removed the shelf and light cover, then removed 3 screws from the ice make. Then I removed 6 screws from the moter cover (back wall of the freezer) and removed it. I then removed the 2 screw holding the moter. This is where the soldering iron comes in. The wire leads from the old motor were molded into a 3" rubber holder and the end wire plastic connector held 6 prongs (2 from a thermo tube). The new motor only held the 4 moter prongs, 2 were empty. To resolve this problem I cut the wires on both the new and old motor. I then attached the old connector to the new moter with the soldering iron and shrink tubing. Replaced all the parts I had removed and started it up. Works like a champ.....
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
I knew almost as soon as I found the frozen milk that the air-flow diverter, whatever it's called, had broken. It's a plastic part that opens and closes to allow cold air from the freezer into the fridge side.
Step one: clear off the top two shelves and take them out.
Step two: remove the lower piece of the assembly. It pops straight out at the top and drops down after that. If you pull the bottom straight out, you may break the bits that holds it to the fridge wall.
Step three: remove screws holding in light, and then the screws holding in the AASM COVER FF INLET K (wish I had a better name for it).
Step Four: Unplug the unit from the fridge wall.
Installation, reverse, except maybe unplug the unit earlier.
I took the four screws out of the ice basket and removed the plastic cup pieces. I then lifted the scress shaft up and put the new cup in. You have pull up very hard on the screw shaft and use two thin flat metal puddy knives to disingage the two plactic stays on each side of the shaft holder. The plactic housing around the screw shaft did not brake, however. I then put the screw shaft and the cup drive in place quite easily. Works fine.
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel