Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED. Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
This seems to be a design problem because I have to replace this part about every other year since we bought it. I tried to talk to GE but all they want to do is send a service man out to replace the part for about 100.00, But I do it for around 15.00. I just think they should find out why the rubbe
The repair is easy, just pop the grill off around the ice and water door, then there are 4 screwws to take out so the touch pad can be moved out of the way to unsnap the old door assm. and snap in the new one and wait about a year and a hald to order another one!!!!!
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
while cleaning the fridge my pan cover glass shattered
I simply did a google search search for my model number, found the part, thanks to the schematic that is on the site and ordered it. It fit perfectly where the old glass shelf was and now I have restored my shelf space. Thanks PartSelect
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
I followed the instructions found on this website. I removed the control panel by inserting a small Phillips screwdriver in the three holes at its bottom. I used the same screwdriver to pull the dispenser assembly down but could have used a larger one. The microswitch could be seen in the assembly at that point and was easily removed by opening the "fingers" that held it in place. I attempted to pull one of the terminals off without using a pair of needle-nosed pliers and ripped the wires right out of the terminal(I was able to find a replacement at Radio Shack). Low and behold after reinstalling the new part, it did not take care of the problem.
My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
water leaking from grommet tube assembly at back of fridge
After thawing out freezer pushed water supply tube out from inside freezer diconneted the supply line from the valve assembly by pushing in the bushing with my finger and inserting the new line. Sadly that wasn't the problem!For anyone with the same symptoms of ice building up on your ice maker, to the point where it clogged the water supply line and started leaking from the grommet assembly. The problem is the valve not closing when the ice maker does not need any water. so I ordered a new valve and hopefully that will fix my problem.
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!