In my specific appliance the water valve is located in the bottom right hand corner looking at it from the back. To get to it I remove the thin layer of cardboard the covers the back of the fridge. I then proceeded to disconnect the 1/4" copper tubing which is the water feed coming out of the wall. Then I removed the screws that hold the valve assembly in place. I took the water valve out and removed the electrical connections as well as the plastic tubing which feed the water dispenser and the ice maker. To install the new water valve it was just a matter of reversing steps.
Used pliers to remove the residual broken stud that was still attached to the wall of the refrigerator, and then just pushed the new part in place. The longest time was spent in removing the food and crisper drawers.
Even though my wife said that our icemaker broke, there was actually nothing wrong with it. It was the valve that let water flow in during the 'harvest' cycle. A real easy way to test the icemaker without voltage and current measurements, is to fill the tray by hand with a little cup of water; wait till the water freezes and see if the maker dumped the ice into the bin.
Unplugged faulty ice maker, removed two screws holding it to the refrigerator and took it out. Reversed the operation with the new ice maker and after a few minutes presto, we have ice.
It was pretty straight forward. Remove the two screws that hold the unit to the wall of the freezer. In my case, I had to use a different ice maker than what came with the frig. In order to install the replacement unit they sent a wire adaptor so it would attach to the existing wiring. That too was all fine and dandy. The only problem was that the end of the wire adaptor did not fit through the existing hole in the rear of the frig. I used a utility knife to cut through the thin metal lining. That worked just fine. However, I could not cut through the insulation because I could not reach it through the small hole. The excess wire was supposed to be pulled through the hole and out through the back of the unit. So now the excess is between the wall of the freezer and the insulation. The unit is working wonderfully. In fact, it is making more ice than I can use. I am very pleased with the replacement unit. This is the 3rd ice maker that has been in this frig. All the others had a design flaw that had a leak in the rear of the unit. This caused all the ice to form into a big block. The replacement unit has not had this problem so far. Thank you for allowing me to explain my situation so that maybe others may benifit from my experience. Thank you. Jack
bottom of fridg. would not get cool. Temp was 50-60degrees. The freezer compartment worked so I knew it was not the compressor.
I removed the fan housing in the freezer section by removing all the screws. (7) There are two screws behind the vents. I did not have an ice maker to contend with so this was very easy. There is only two wires to disconnect....the ground wire and the electricity supply. Then you remove the unit from the back of the housing cover by removing two screws. Then the motor is removed from it's housing by removing 2 more screws. 1...2...3 and you're ready to reverse the procedure. I am not mechanically inclined and this was easy. Saved myself perhaps $120.00. Repair folks wanted mininum of $60.00 just to come out. Part and shipping cost me 33 bucks.OH, DON'T FORGET TO UNPLUG THE FRIDGE. :>)
If you think you probably can't do this, you're like me... but you just had to try because you needed the part anyway right? This really was quite simple, a lot easier than it sounds from the description and saved me probably $75 I'd have had to pay a tech to do it. Just unplug fridge, yank that water spill tray out, yes yank, it's a bit hard to do that if you've not done it before. After that remove the 3 phillips head screws you just gained access to. Lift panel frame up then out. Disconnect wire harness plug and set that frame aside. Take out next screws exposed to free the unit. Tilt unit out and remove the two little screws and shims holding actuator in place. Remove broken one. Put new one in. Reverse all actions taken thus far. Plug fridge back in and have a drink of water like nothing ever happened. : ) You can do this!
First I disconnected the power cord, then removed the screws that held the bracket that holds the base for the water-filer in place. I then disconnected the water lines(intake and outflow). Next I removed the screws that held the water-filter's base in place. I then disconnected the release lock mechanism for the filter and finally removed the water-filter base. I did the reverse to install the new water-filter base. Previously I had tested the intake water line and noticed the water was flowing with enough pressure upto the water-filter's base but no water was exiting thru the outflow line, which leads to the Ice-Maker and Dispenser. I had tried changing the filter but that didn't solve the problem it was then I had realized that the Base was the problem. The actual problem was the spring-loaded valves for both the intake and outflow lines, which had a plastic prong that protrudes out of the base that is triggered by the filter when installed. The two prongs were worn-down so the filter wasn't activating the spring-loaded release valve to let the water thru. As for the light, I just unscrewed it.
The ice dispenser would only dispense crushed ice, Fridge door cluncked when opening and closing
For the ice dispenser, I read a blog that pointed me right to the solenoid that controls the linkage for the crushed /cubed ice.I first unplugged the fridge. Then removed the ice maker basket. Removed 2 ea screws from each side of the supports of the lower brackets. Then lifted the tray assy off the mounting bracket, moving the front of the bracket down you can then unhook the power/control connector. The tray then comes right out. Once out you remove two screws that hold a plastic plate on. With this removed you can see the solenoid that actuates the linkage for the ice cube and crushed ice. You then remove 2 ea machine screws that hold the solenoid in. Remove grd. wire. and pull power wires off tabs. You can then remove the solenoid by sliding it out of the plastic retainer. With it out you install the new plunger and reassemble in the reverse order. 15 mins tops.
The main Refidgerator door, made a cluncking sound. Lube didn't help. I removed the door by removing the top screw from the plastic cover, then slide it forward, then remove the two screws that hold the hinge on and then lifting the door off, once off the lower nylon hinge bearing comes right out of the door, the plate is removed with a screw driver. Installed in reverse order and cluncking was gone. 10 mins
water leaking(pouring) from the filter into the refrigerator
Pushed the button on the filter in the fridge, the cartridge popped out and in with the new. That simple. Prior to replacement the water was leaking, although it was still producing water and ice through the door. When the filter was out, no leaks, but no water and ice! Just needed a new filter.
pulled fridge from wall, removed card board cover, unplug the fridge. turn the water off to the fridge. remove the water source from fridge first then remove 2 screws that hold the valve. then the wire plugs. hoses.. they were color coded.
Slide off drip tray at bottom of ice/water compartment.
Remove the 3 screws along bottom edge of face plate. Slide face plate upwards slightly to disengage tabs holding top of face plate to fridge door. Pull face plate slightly away from fridge, reach behind plate, and disconnect wiring harness. Set face plate aside.
Remove 3 screws holding ice/water actuator mechanism to fridge door. Disconnect wiring harness on left side of actuator mechanism. This allows the left side of mechanism to swing outwards.
Looking down on top of mechanism, loosen the two screws holding the small, metal retaining plates for ice actuator. (The metal plates hold the ice actuator pivot pins in place in the actuator mechanism). Once the two screws are loosened, the metal plates can be moved to the side to free the ice actuator.
Remove old ice actuator and replace with new actuator. NOTE: Ensure the black ice door flap regulator (the thing with the gear teeth) stays engaged with the gear on the damping mechanism while installing the new ice actuator).
Move the metal retaining plates back in place over the ice actuator pivot pins and tighten both screws. Move the ice/water actuator mechanism back in place and re-connect the wiring harness on the left side. Re-install the 3 screws holding the entire mechanism in place.
Re-connect the wiring harness to the face plate and slide the tabs at the top of the plate into the holes in the fridge door. Slide face plate down and line up the 3 screw holes at the bottom of plate. Re-install the 3 screws. Re-install the drip tray. You're done!
Nylon door hinge bearing on the bottom of refrigerator door broke
First I removed the contents from the door. Second, I removed the exposed bolt on the top hinge(per the manual instructions) and then I removed the plastic hinge cover. Up next was to remove the remaining two bolts from the top hinge. I should, at this point, say it is much easier to have someone help steady the door for you so it doesn't fall off the refrigerator. Now remove the door and the old nylon bearing. Replace with the new bearing and replace the door. This repair couldn't have been easier.