freezer defrost and then after some time would work.
one repair man said I needed freon. sears repair man said my evaporators leaked. and should buy a new fridge. I installed the parts for less than $30.
dried the freezer compartment removed back panel and asst parts. removed screws from evaporator assy and replaced def therm. soldered leads/wing nuts. removed cover from sensor temp and again connected leads. working fine.
Parts Used:
Defrost Thermostat Temperature Sensor
  • anthony from burke, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
92 of 96 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace Broken Drive Cup
This was the second time in two years I had to replace a broken drive cup. Remove four screws that fasten the ice bin to the frame. Remove one screw that fastens the cube-crushed ice lever to the bin. Do not remove the lever and spring from the bin. Move the lever to expose the connection to the cube-ice shield. Push the lever to compress the spring and remove the lever end from the cube-ice shield. The cube-crushed ice assembly is a press fit and should pry away from the bin. Two issues. 1- The threaded plastic bearing on the dispenser end had turned all the way in causing the end of the dispenser screw shaft to bore through the housing and trap the shaft onto the housing. I had to insert a pry between the housing and the dispenser mechanism to release the shaft from the hole it had bored. Then the dispenser mechanism separated easily and the drive cup replacement was simple. 2- Why was the drive cup breaking? When I used "quick ice" the freezing tray over-filled causing the cubes to freeze together at the top. The bonded cubes then got trapped in the dispenser screw and jammed a lump of ice into the end of the bin causing enough pressure on the plastic drive cup to break it. Lesson - Check the ice bin frequently for frozen lumps of ice. If present, empty the bin and make sure only properly formed cubes are present. Run the dispenser frequently to prevent ice cubes from freezing together.
Parts Used:
Ice Dispensing Drive Cup
  • John from Henderson, NV
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
91 of 105 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warm freezer and no ice
This story starts with a GE side-by-side refrigerator that has always had wide temperature swings and a temperamental water dispenser. The ice maker was not making ice, and the built in digital thermometer showed it was running warm. I suspected that the heat exchanger was full of dust and so looked there. What I found was that the condenser tank was hot to the touch and the fan wasn’t running. As an experiment, I aimed a fan at the it for a while I saw that the freezer temperature dropped back to normal.
.The fan is marked as 11.2 DC so I checked for voltage at the fan and found some. With three wires and no wiring diagram I wasn’t sure this answered all the questions, but hooking the fan to a 12 volt power supply didn’t get it to spin.
I priced parts at a couple websites before using partselect.com . They also have a good diagram to look at (Sears diagrams are really poor). I ordered the part with 2-day shipping; it arrived on time, was correct and fixed the problem.
Parts Used:
DC Condenser Fan Motor - 12V
  • Paul from Suwanee, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
94 of 124 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Parts Used:
Ice Maker
  • Gerald from Benicia, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
89 of 122 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water continuously pours out of the icemaker
A week earlier, we had frozen water all over the freezer section which obviously dripped from the icemaker. We turn off the icemaker and cleaned the freezer. Upon turning the icemaker back on, water continuously pours out of the ice tray. This time, even turning off the icemaker does not stop the water from flowing through. I checked and cleaned the water valve, reinstalled it and it still does not work. I had to crimp the water line and even remove the water filter to make sure there will be no water leaks.

When I got the new water valve, installation was a snap as I have already removed the old one. After installing the new valve and putting back the filter, everything is back to normal.

Procedure for removing/replacing the water valve:
(1) Unplug the refrigerator and move it so that you have some working space in the back. If there is a mechanical valve in the water line, close it so that when the hoses are unplugged, there will be no spills. If there is no mechanical water valve, you can simply crimp the hose with a rubber band or a cable tie.
(2) Use an adjustable wrench or a screw driver to remove the screws on the bottom panel. My refrigerator has 4 big screws and 1 small one that is used to anchor the water hose.
(3) Pull the panel up slightly to remove it. The water valve is mounted with one screw at the bottom-left corner.
(4) Use a screwdriver to dismount the water valve.
(5) Unplug the electrical connections to the water valve. My refrigerator has one Brown and one Blue connector. Remember which plug goes to which connector.
(6) Place a towel under the water valve and use the adjustable wrench to remove the main hose connection.
(7) Next, remove the hoses that to into the water valve outlets. On my refrigerator, these hoses are of different sizes and have quick-disconnects. I simply have to press on the collar at end of the hose, pushing it towards the valve to release the hose, then pull on the hose.
(8) Prepare the new water valve by removing the plastic cover that protects the connector for the main water line.
(9) Connect the main water line to the new valve using the adjustable wrench.
(10) Connect the two hoses of different sizes to the valve. You only have to push them all the way into each valve and slightly tug on them to make sure they are locked in place.
(11) Re-connect the Brown and Blue electrical connectors to their original location.
(12) Mount the new water valve into the back of the refrigerator (one screw).
(13) If possible, quickly check that the new valve is working properly: If you have a mechanical valve in the water line, open it and make sure there are no leaks near the valve or inside in the icemaker. You may have to plug in the refrigerator power to complete the initial test.
(14) Replace the back panel with the 4 screws and anchor the hose to the back with 1 screw.
(15) Once everything is back in its place and the refrigerator is on, cycle the water dispenser several times to run fresh water into the hoses and the new valve.
Parts Used:
WATER VALVE WITH GUARD
  • Noel from San Jose, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
72 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
Parts Used:
Ice Maker
  • Dan from West Bloomfield, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
82 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Parts Used:
Ice Maker
  • Laura Beth from Mandeville, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
76 of 99 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Getting ice but not water from the dispenser
On the web site I explained the problem and the solution was immediate. I went to the installation video and was instructed how to install the double outlet valve. It took about 10 minutes to take out the old part and install the new one. I didn't have water immediately so I viewed comments by others and learned that I may have a frozen line in the door. I tried thawing out the line and in about 3 hours and I had water. I figure I saved about $200.00 by doing it myself. Thank you partselect.com
Parts Used:
MWF BYPASS WATER VALVE WITH GUARD
  • Gary from North Salt Lake, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
75 of 98 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
not cooling, water in refrigerator
For several years, had problem with water accumulating in the bottom of the refrigerator...took out the "custom cool" drawer and assigned my kids the responsibility to dry it out daily after supper (about a fourth of cup of water daily)...the water was condensing and dripping down the left side of the refrigerator... NOT coming from the refregerator evaporator drip pan area. Then the refrigerator and freeezer had erratic cooling...paid 4 grand for this GE stainless steel on the front/sides frig about 5 years ago... then my wife said she wanted a new refrigerator...what the heck...went on to numerous websites and finally decided to do my own "overall"...had nothing to lose except the price of the parts. A helpful web site is the GE technician site at...www.manualinstruction.com/wp-content/uploads/2011/10/ge-sidebyside.pdf. I ordered the four thermisters, a new freezer defroster (the old one was probably OK...the freezer coils were not "iced Up"), and a new defroster thermonmeter. While I was at it, I ordered a new refrigerator evaporator drip pan that was rusting a bit. As per other instructions in this website, just spliced in the new thermisters,used wire twist caps and eletrical tape to seal them. The GE site is a bit more elaborate on the "correct" way to do this. The refrigerator evaporator coil is a bit tricky...see the above ge site...but I just cut the rubber thermister holder down the middle and then tracked the thermister through the holder and stuck it in the block and taped the holder back together...(removed the block first ) and then zip-lined the block back to the coil like it was originally. It was about 3 hours to do everything...and guess what...temp in the freezer is -5...temp in the frig is 36...and NO MORE WATER IN THE BOTTOM OF THE REFRIGERATOR, NO MORE WATER DRIPPING DOWN THE LEFT SIDE OF THE REFRIGERATOR...what will my kids do...I feel like the refrigerator guru now. Wish I had done this several years ago. The parts I ordered came in 3 days. I'm lovin my refrigerator now and my wife is lovin me. It's really easier than I thought it would be...the GE tech website has some "diagnostic" info to isolate different problems... but I just decided to replace "everything" since the parts were not that expensive and it was going to be a "do or die" on getting a new refrigerator.
Parts Used:
Defrost Thermostat Evaporator Drip Pan SHIELD LIGHT FZ Temperature Sensor Crisper Cover Glass Insert Shunt Sensor Refrigerator Temperature Sensor Cover
  • Gene from The Woodlands, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
67 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
Parts Used:
DC Condenser Fan Motor - 12V
  • Ray from Bensalem, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
74 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Door Recess Retainer Dispenser Door Recess Crank Recess Door Spring
  • Turcotte's Housing Service, In from Newmarket, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
70 of 92 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice buildup in the door of freezer
Pulled the ice/water control panel off using the three holes under the lip. Pops off pretty easy. Next came 4 screws holding the chute for the ice. Two bottom screws were very rusty, top two look brand new. Watch the wires. Replace the solenoid assembly by unplugging wires leading to the board, then removed the plunger over the top of the hook on the far right. Went ahead and replaced the dispenser door assembly or flapper. Plugged refridge back in and pressed the ice dispenser handle and listened for the solenoid to cycle. Perfect. There is a little delay before you hear the flapper fall into place. Saving rest of parts just in case they are needed next time.Thanks to everyone who wrote in to show how easy it would be. No telling how much a repairman would have charged me.
Parts Used:
Dispenser Door Solenoid Assembly Refrigerator Ice and Water Filter Dispenser Door Assembly or Flapper Door Recess Retainer Dispenser Door Recess Crank Recess Door Spring
  • Walt from Alabaster, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
66 of 88 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dropped something on the light switch and it broke off
we just pried out the old switch and pulled it out the rest of the way with a pair of needle nose pliers. Pulled off the wires on the broken switch and reattached to the new one and just slid/clicked it back into the hole.
Parts Used:
Light Switch
  • Lorinda from Dallas, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
57 of 63 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
Parts Used:
Evaporator Fan Motor
  • David from Romeo, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
65 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker failure due to chunks of ice building up in tray
My problem began with having to replace the auger due to damage (broken blade). Unknown at that time the unit was having a defrost cycle issue. Once auger was repaired, then the motor to auger failed. Once repaired the GE unit then began shutting down without warning. Mother board replaced. All was fine for two weeks then noticed odd performance by ice-maker (chunks of Ice again)and frozen package containers showing signs of dampness and then refreezing. Read through the Parts Select web site to see what other users may have had gone wrong with their GE's and what the parts overview section may reveal for me. Found that the defrost thermo and temp-sensor controlled defrost functions. The parts were cheap, $20.00 for the pair so I replaced them both since they are both located next to one another in the freezer compartment. The repair video furnished on the P/S web was great and very accurate. The entire job only took about an hour. The repair video indicated using wire-nuts and electircal tape Instead, I chose to solder the wires and use shrink-tubing to provide the moisture barrier. PartSelect folks are great not only for their parts pricing but also for the informative videos. The GE works better than ever
Parts Used:
Defrost Thermostat Temperature Sensor
  • Terrence from Escalon, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
62 of 83 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!