35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
evaporator coil in freezer section fozen solid, refer not cool
To remove freezer door, push white tabs, inside rail toward back, remove door and rails as one unit. Unscrew plastic rail support on one side, remove ice maker, then back panel. Cut off thermostat, strip old leads, match colors, twist copper wires together, then crimp on new part using connectors provided. Reassemble, hardest part was figuring out how to remove freezer door. Check for continuity between heater lead and white terminal of icemaker plug just to make sure the heater is good while everything is apart.
Could not figure out why this was happening suddenly. Then remembered I had recently changed the lid to one I had stored for over two years in the garage. They had sent me a replacement lid when the unit was less than a year old because the origianl had a crack in the clear section. Noticed it seemed a little warped. Thought I would replace it to see if that solved the problem. We had to replace the side panel of the draawer because the warped lid had broken the peg off of one side. I didn't want that to happen again. The new lid did the job....This company is the only one I will use in the future for my appliances. Very easy to find parts and the pricing was better.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
you need to take the deli drawer out, make sure your flat head screw driver is large enough for the head of the screw as screwing into the plastic is a bit difficult. Other than that there are 2 screws and its pretty easy.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Snapped into place with the attached clips. Could not be easier. Really great service from PartSelect--got here faster than I expected. This was a great service--would recommend to everyone!
Back of freezer froze up and not getting cold in refrigertor.
I got on the web blog and saw a conversation on here that sounded just like the problems i have been having with my unit. After reading every thing about it i ordered the part needed and installed it. I let the fridge thaw out over night and started it up the next morning. Its been two month since i installed the part and it is working great!!!