Door would not automatically close.
Symptom: Door did not close automatically. Also had found small chunks of black plastic on the floor. Refrigerator door was slightly lower than the freezer door.
One false start because I did not realize both of the door-closing cams had disintegrated and I had only ordered the cam without the hinge.
Purchased part 290199 Hinge Assembly. It came with matching door-closing cam. (Had not known so I also purchased the cam 297995 separately). Next time I will know to only purchase the Hinge Assembly.
Replacement procedure took about 20 minutes including removing and replacing door shelves and their contents. Two people involved.
1. Remove all door shelves with contents and other contents on door.
2. Remove the top Phillips head screw holding the decorative plastic on the top.
3. Remove the two top hinge screws on top of refrigerator using metric #8 socket wrench. Second person made sure door did not fall off.
4. Lift the door off the bottom hinge pin. Second person holds door on it’s side.
5. Take off the bottom refrigerator cover
6. Remove the bottom hinge assembly screws using metric #8 socket wrench.
7. Mount the replacement bottom hinge assembly and tighten the two screws.
8. On the door bottom, remove the outer screw and loosen the inner screw using metric #8 socket wrench.
9. Replace the door-closing cam (or what is left of it) with the cam in line with the door and cam bumps away from the door.
10. Place the door back on the hinge pin (one person holds while the other person maneuvers the door bottom).
11. Replace the top hinge and reinsert the screws on top of the refrigerator. Dress the door so that it does not press hard on the rubber door gaskets (or the door will fail to shut automatically). Tighten the screws.
12. Replace the decorative plastic over the top hinge.
13. Open the door and replace the bottom refrigerator cover.
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple. Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use. The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap. After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.
The icemaker started making ice very soon after turning the unit on.
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Removed 2 phillips head screws to remove ice maker (could have just loosened them) Pulled fan off of shaft Removed 2 phillips head screws on motor bracket , disconnected three motor wires & removed motor. reversed process to install new motor & fan blade. Space was a little tight for two hand and arms, but do-able.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Order 2 cams as recommended in other posts. I didn't realize until the project was finished that the 2 cams fit together to tilt the door toward the refrigerator and force the door to catch. 1. Removed all items from door storage. 2. Removed top hinge cover held by single screw and top hinge plate held by two bolts. 3. Lifted up door to clear bottom hinge pin and removed door. 4. Turned door upside down and removed bottom hinge assembly held on by two bolts. 5. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door. 6. Drilled out the rivet that holds the lower cam to the bottom hinge pin. 7. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). NOTE: The metal shim that goes between the cam riser & door was also broken, we used a small washer instead of the replacement shim. 8. Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. 9. Placed cover on upper hinge assembly and secured with original screw. This is a project my husband and I completed together :) Perhaps we will store lighter items on the door to lessen the chances of the cams deteriorating again.
Door closing cam had disentigrated over the past 12 years.
I read over the other posts here and went with jacking up the fridge door and setting it on (2) 2x4 studs. A nut driver was used to remove the bottom hinge. I then drilled out the rivet that held the old cam in place and then used a 3/16 rivet to secure the new cam. A rivet is not necessary as you can also use a nut and bolt to hold the cam in place. It took less time to order the part and install it than it did to drive over to the appliance parts store and pick it up. I ordered around 10 am and the part was here the next day at 2:00 (without special delivery costs). By 2:30 it was on my fridge.
The OEM auger pitted and rusted. My ice was coming out brown. I had cleaned it before, but in no time is was back to 'spiced' ice cubes. I cleaned the entire ice bucket and disassembled, ordered the part and re-assembled. Now the disassembly was a different day than the assembly. It's a good thing the parts diagram was on the web, I am no Thomas Edison when putting things back together. It is pretty general though. I sand blasted the tin cover and re-painted before buying a new one. That had rusted too. Before that expense, I thought I would try it. Be careful of the bucket as it can crack. I am not sure when mine was cracked, but I noticed it this time. If you are contemplating the purchase of a new auger - don't. The new one is stainless and the old steel and chrome is a joke. The inside of the freezer where the bracket spins the auger is rusty too and the old auger will rust again in no time. Buy a new one for under $50 shipped to your door. Another note, be sure to remember what screws came from what hole. It will eliminate the guess work when assembling. Also, the spring on the arm that controls the crushed ice function, note the position before tearing apart.
repairman came looked it over said problem was thermostat control which was not made anymore and left charging service call $190.00 I went online found the control for $160.00 received it in 3 days put it in 30 mins later working fine.