Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refigerator door would no longer self close
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!
The refrigerator was leaking water from the freezer section.
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.
Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.
After the panel is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.
Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.
Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.
Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.
Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.
Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!
P.S. Don't forget to put the food back in the freezer.
de light flasing on freezer door electronic disply
I removed the back wall panel inside the freezer compartment(approx. 6 screws). The coils were very iced up. I manually defrosted the the coils with a hand hair dryer. I then removed the 2 screws from each heater element and the clip-on thermostat from the coil. I pulled the elements, thermostat and wiring harness(item 230 on parts diagram) out of the freezer compartment and installed the new assembly. Electronic self-check of the defroster indicated normal. Further checks indicated the lower heating element was open.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new. thanks.
To repair the light switch you need to replace the control board since the switch is not replaceable. The control board is easily gotten to by removing the outer cover, which snaps out, the removing the screws that hold the housing for the control board, make sure you disconnect the power and turn off the water supply before you remove the outer cover.. The board is held in place by a bracket which has two screws, make sure you disconnect the two wiring harnesses before the bracket. Once you get the bracket off the control board slides right out. To install the new board, just reverse the process.
Changing the handle is accomplished by remove popping out the top and bottom trim pieces, then remove the upper and lower screws from the handle. Reverse the process to install the handles.
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install. 1) Turn off water line and unplug power. 2) Pop off front panel plate at ice cube select switch area. 3) Unscrew 4 screws that holds control panel housing in place. 4) Remove panel assembly by disconnecting two different wiring plugs. 5) Unscrew 2 screws that allows access to control circuit board at end cap. 6) Remove circuit board by sliding it out of the assembly housing. 7) Install new circuit control board in assemble housing and screw on end cap retainer. 8) Attach two electrical wiring plugs. 9) Install control board assemble housing into frig opening and secure with 4 screws. 10) Install front panel plate (pops on). 11) Plug in power and turn on water line.
The cam broke apart and the pieces were on the floor. The door did not close automatically. This was on the freezer side.
I used the same steps as described in other descriptions listed here. Since I was changing the hinge assembly on the freezer side the difference I discovered was that there was a nylon water hose inside the hinge assembly that I did not at first know how to remove. I finally called a repairman I happened to know and following his instruction simply snapped the hose loose where there was a connector and placed a cloth under it to catch the moisture that drained. Having done that, the rest of the assembly went just the same way as the other instructions listed here said that it would. Door now functions like new.
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.