Models > NS22H8A > Instructions

NS22H8A Admiral Refrigerator - Instructions

All Instructions for the NS22H8A
31 - 45 of 126
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
clicking sound
unplugged the power and removed the cardboard back Unplugged the part and power from the side of the compressor Plugged the power and new part back in to the side of the compressor and replaced the clamp Plugged in the power cord to the wall outlet and the refrigerator started to hum Job done Thanks
Parts Used:
Relay and Overload Combination
  • Ronald J from TULSA, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Build Up On Evap Coil
Removing the old heater coil was a bit of a task as you need to take off all the brackets holding the heater coil and then remove the wiring from back of the coil. Installing the new heater coil assembly in the brackets and feeding the wirings back up to the top was a major task. Need to have long arms as the heater is located way back in the freezer compartment. The part was the exact match. The part was delivered in 2 days. Thanks alot. Will use your site again.
Parts Used:
Defrost Heater - 500W 115V
  • bobbie from belleville, IL
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Deli and Crisper Drawer handles cracked
I unboxed the new drawers, measured and cut some 1/8 plexiglass strips to fit. I then glued the strips on the inside of both drawers to strenghten. The original and replacement drawers lack strength at the corners and crack. This was the third set I have replaced. Should not happen again.
Parts Used:
Crisper Drawer Deli Drawer
  • David from Garfield, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Parts Used:
Light Bulb - 40W
  • Yafa (and David) from Bothell, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Parts Used:
Condenser Fan Motor Kit
  • Tonya from Grand Prairie, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had the correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
Parts Used:
Defrost Heater - 500W 115V
  • Rick from Livonia, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace broken ice cube trays
No repair needed. I had only to wash the new ones and use them.
Parts Used:
Ice Cube Tray
  • C MARTIN from TAMPA, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Parts Used:
Condenser Fan Motor Kit
  • John from Holden, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One side of the dairy door broke right at the little tab site.
I have to say the packaging of the diary door was A+++ It took less than a minute to snap out the old door (that I had tried to hot glue) and snap in the new door. My story is what a fantastic sales department you have. I submitted my order for the dairy door as well as new shelving hinges. The hinges came in right away; however I received an e-mail saying they no longer had the dairy door. I received a message on my cell phone that the sales lady She said she located a couple of dairy doors in other warehouses and was going to check their availability. Sure enought, it took a week or so, but she did come through with the dairy door for me. I was told they only had a couple left and that they were not making them any longer. Whoever this sales lady is.... three cheers for you what an excellent job. She really did not have to pursue the order any further than her own warehouse but she did - thank you for your excellent service!!!
Parts Used:
Dairy Door
  • Deborah from Walker, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dual light socket in fridge shorted out
took old socket out, ordered replacement part, dual socket no longer available. Turn off power to appliance, attach new single light socket, screw light socket and light socket holder back into place. Turned on power and it worked. No instructions included in packet, attached wrong first time, blew fuse, attached socket a different way, and it worked.
Parts Used:
Single Lamp Socket Kit
  • Kimberly from Blue Springs, MO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Parts Used:
Condenser Fan Motor Kit
  • Karl from Wellesley, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator constandly running
Turned out the defrost heater has burnt out in the freezer compartment on both heater tubes. To get to it. 1) take out all the shelves 2)remove the light bulb 3)unscrew 6 screws for back panel 4)Mine had a lot frost build up on the evaporator coils which I used a portable heater to defrost. which it took about 2 hrs to get all the frost thawed out. 5) Defrost heaters are located below each of the coils remove 2 screws on each plate there are 2 plates holding the heaters in place. 5) You may have to bend the sheet metal in order to get the heaters out and trace the wires to where it connects to towards the top or the freezer. 6) Put in the new heaters and plug in then put back together. 7) I also replaced the Defrost thermometer which it is easy to replaced while I had it apart. Now the fridge works perfect just like new.
Parts Used:
Defrost Heater - 500W 115V Defrost Thermostat
  • David from Clintonville, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights did not work
pulled out old socket and replaced supposed to be a duel socket but no longer exists
Parts Used:
Single Lamp Socket Kit
  • Daniel from rochester hils, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the NS22H8A