Models > NS22H7H > Instructions

NS22H7H Admiral Refrigerator - Instructions

All Instructions for the NS22H7H
16 - 30 of 123
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stopped-freezer not performing etc.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Parts Used:
Condenser Fan Motor Kit
  • George from Glenwood, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer section would work OK but the refrigerator stopped cooling
Tips from internet forums helped me figure out the problem: The defroster heaters were not working and the freezer side would frost up and prevent cold air from entering the refrigerator side. I removed the drawers, drawer slides, ice maker, then the back panel to expose the cooling coils. You can check the heaters for continuity before rempving them by disconnecting the two lead wiresonce you have the back panel removed. Not getting any continuity, I removed the old heaters after defrosting the coils. Removing the heaters was the most difficult part as they are a little "long" for where they fit, but with care it can be done, the same applies to installing the new heaters. I had to cut the connecting wire on one of the heaters to remove it, but got the new set installed OK. Works fine now, the bottom heater was defective, and since the are wired in series neither one will work independently. Everything works fine now, problem solved.
Parts Used:
Defrost Heater - 500W 115V
  • Kenneth from Laingsburg, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost heater shorted out.
Unplugged refrig., emptied freezer, removed ice bucket drive, removed back wall of freezer, used blower side of vac to defrost coils, remvoed glass heaters and pulled a chase line thru as I removed old wires. Replaced heaters and chased new wires using chase wires.
Parts Used:
Defrost Heater - 500W 115V
  • William from Bay City, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator coils would freeze up solid
Removed everything from inside freezer compartment (food and shelves) Removed inside backpanel that covered the coils. At the top of the coils is where the thermostat was attached. Removed old one and installed new. Has been working since.
Parts Used:
Defrost Thermostat
  • Walt from Sutter, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not defrosting
Removed existing and installed the new part. The hard part is reaching to the back of freezer as it not very wide and is farily deep. Hard to get to arms in at the same time.
Parts Used:
Defrost Heater - 500W 115V
  • DON from CHANDLER, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Parts Used:
Condenser Fan Motor Kit
  • Ernie from Windsor, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer and fridg would not cool.
Turn off power. unscrewed and removed the panel in the freezer compartment exposing the defroster(6 screws). pulled off the two defroster wires from their lugs. Removed the two plates (4 screws) holding the two heater elements. unsnapped the two heater elements from the plates. installed new heater elements. attached the plates.attached the two wires to the lugs.done
Parts Used:
Defrost Heater - 500W 115V
  • Dennis from Palm Ciity, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Parts Used:
Light Bulb - 40W
  • Carl from RIVERSIDE, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
clicking sound
unplugged the power and removed the cardboard back Unplugged the part and power from the side of the compressor Plugged the power and new part back in to the side of the compressor and replaced the clamp Plugged in the power cord to the wall outlet and the refrigerator started to hum Job done Thanks
Parts Used:
Relay and Overload Combination
  • Ronald J from TULSA, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the NS22H7H
16 - 30 of 123