The Dryer would not get hot.
I removed the two screws holding the access panel, and removed the access panel. Then removed the lower air duct. I then checked the burner, The solenoid was not opeing the valve for the gas. I order the coils, in two day I had the coils and installed them. The dryer is working great.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Jerry from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch did not turn off dryer when door opened
Switch can be removed from outside of dryer and your video described the repair as having to work from inside dryer. But since wires were still attached to old switch, it could be popped out and wires switched. Since there were three wires on new switch to allow it to turn on and off a circuit, it was useful to check the resistance of the switch compressed or released to be certain I was attaching the two wires to the right two poles of the new switch. But that all required only a couple of minutes. Thank you.
Parts Used:
Door Switch Kit
  • paul from madison, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
13 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating up
Unscrewed 4 screws,pulled off front of machine.Unscrewed 2 screws holding coils on,unplugged coils,installed new coils,plugged in coils,reinstalled 2 screws for hold down brace.Reinstalled front cover,plugged dryer into outlet(remember to unplugged dryer before working on it).started up,instant heat,works great.thanks Partselect for helping me out!!!
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Richard from New Windsor, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The moister sensor broke away from it's two fasteners inside the dryer drum.
Unscrewed the two fasteners, rerouted one wire using a wire coat hanger, plugged in the new moisture sensor to the two wires and fastened the the sensor in place using the two existing screws.
Parts Used:
Moisture Sensor
  • David from Preston, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flame turning off too early
Used the computer to display error 02. Found Temp control shorted. Needed to replace Thermistor temp control. Thermostat, Cycling I purchased for spare part. All is well.
Parts Used:
Cycling Thermostat - Limit 135/155 Temperature Control Thermistor
  • Anthony from Staten Island, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Socket set
14 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer door latch broken, using duct tape every time to dry clothes.
Piece of cake. Used flat screwdriver to pry out female part on cabinet side, same with the male part on door. Every new replacement part was tight and operated like new. Thanks Part Select, you'll be forever on my list of online parts buying.
Parts Used:
Door Latch Kit
  • Scott from Palm Bay, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close would not get dry. Dryer started normal. Timer would not time out.
Getting to any of the parts in the Maytag dryer is easy. Tip the dryer back and slide a 4 x 4 block under the front edge. You remove the whole front panel after you remove two screws at the bottom corners of the front panel. You need to tip the dryer back to get a screwdriver on the screws. Swing the front panel up to release the top of the door panel from the top. Watch the short wires to the door switch. Unhook the door switch wires and move the front panel out of the way. The timer on the top is accessed by re-moving two screws along the top edge. There are four screws. Remove them all and tip the top of the front panel forward. You then see that two screws hold the panel and the other two screws just hold the trim.

The dryer started normal. The drum motor run when the start button was operated. The fluff cycle operated normal to indicate the timer motor was OK. On the dry cycles, the igniter heated up. The gas came on. The dryer run for some period of time and then the flame went off. The thought was that the low temp cycle thermostat sensed the dryer was hot and thus switched over to time the cycle to its end. However, the low temp cycle thermostat tested good with a meter when the sensor was removed from the dryer and heated with a light bulb. Burnt contacts in the sensor were a possible problem. I also though the radiant sensor may be bad and not recycling after it got hot. After time, the igniter would cycle on but the gas flame would not come on. I thought the radiant heater might not be tripping the secondary coil on the gas valve. The gas valve coils tested good. I was checking them cold after the dryer had cooled down. I ordered a number of parts.

I got lucky and did a test on the coils while the dryer was still hot. One of the coils in the dual booster holding coil was going open when hot. When cold it had enough continuity to let the gas valve cycle on once. After the coil got warm it went open and shut the gas valve off. When the coil did cool off, it again had continuity. I was about ready to trash the dryer when I finely found the problem. I am happy I persisted and worked the problem through to a solution. I purchased several extra sensors but saved money in the long-run. I rate this problem at the high end of complexity for the do-it your self home owner to solve. The problem was an easy fix once the real problem was found. Only 4 screws and 3 push on wire connectors (two were on the front panel for the door switch).
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Roger from Westminster, SC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a chirp coming from the unit when it was off.
I replaced the part and it chirped..then stopped and it has been fine for several weeks and now it chirps again. It is like there is a cricket in there. I am hoping it stops again.
Parts Used:
Electronic Control Board
  • David from apollo beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas Dryer would heat for one heating cycle but no gas afterward. Ignitor would glow.
Checked four thermocouples all showed continuity with my multimeter so they were all good. I'd read that the coils commonly went out and that these were the symptoms. Hey, it's very simple in there. Not much else could be wrong. I had a Maytag repairman come out. At first he said the problem was a blocked vent. I knew he was wrong. Then he said one of the thermocouples went out. It was $80 for him to come out. It turned out that his second diagnosis was wrong too. To repair the dryer by Maytag would have cost me $240. I gave him $80 and bought the coils for $37. They are EXTREMELY easy to replace: two screws held a bracket that held two coils. With the bracket off, I took off the old coils and slid on the new ones.
Parts Used:
M Series New Style Coil Kit
  • Jim from Foothill Ranch, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One of the Baffles came loose.
I took out screws holding top to dryer & raised the top & proped it up to gain access to inside of the dryeeer drum. I then inatalled the new baffle & secured it with 2 screws. It would have been better if the part came with new screws.It was hard to determine which was the right screws for this application.
Parts Used:
Tall Baffle Short Baffle
  • Robert from Milford, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken door strike
Removed one screw and took out old broken door strike, replaced with new door strke and put screw back in. Only took two three days to get the part. The dryer is as good as new!
Parts Used:
Door Strike - male
  • Carl from Livermore, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat in dryer
Took off the lower front panel, removed duct piece from filter to blower fan, removed two screws and two wires to thermostat in exhaust ducting, then replaced thermostat with new one. Very easy job and everything worked like new when I reassembled it.
Parts Used:
Cycling Thermostat - Limit 135/155
  • Noah from Maiden, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Short Baffle in dryer drum was broke off
This was fairly easy, I have had the dryer front off before. Unplug dryer from electrical outlet. Pull dryer away from wall. Remove the dryer door, open dryer door there are 2 phillips screws on dryer door hing, remove these crews then lift gently and remove door, across from these screws, where dryer door closes into face cover of dryer remove 2 more phillips screws. From top of face cover, pull out front of face cover and lift to remove face cover of dryer. On each side of dryer on the front, after removing the front cover is a 5/16 bolt, remove these and pull off retaining bracket with a twisting motion. You now can lift the top of the dryer up. You can now see the barrel drum. Rotate barrel by hand so the broken baffle is on top. Remove two 5/16 bolts, and replace new baffle in place. Reassemble in reverse order of disassemble.
Parts Used:
Short Baffle
  • Wade from Lovell, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer shut off before clothes were dry
The old sensor came out by removing 2 screws. I unplugged the two wires from the back of the sensor and plugged them into the new sensor. I reinstalled the new sensor using the same two screws. Of course, I unplugged the dryer first.
Parts Used:
Moisture Sensor
  • Paul from Tamaqua, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
After initial ignition & first heat cycle, gas valve would fail to re-ignite
The good: No need to pull out dryer beyond point where (wall) gas valve could be shut off.
The gotcha: Be sure to wear thick leather gloves to protect your hands. I discovered sharp edges the hard way!
The tip: To loosen gas valve inlet nut and to remove gas pipe from valve, use a bottom-to-top wrench motion. Despite threads being right-handed, this counter-intuitive operation (the thinking is that you are tightening the nut instead of loosening it) is necessary due to nut being located on the valve rather than the gas pipe which reverses the context.
The ending: Wife is happy to be back in the drying business and I'm happy just to have her happy not to mention saving a little $ in the process! Thanks PartSelect.com!!!
Parts Used:
Moisture Sensor Gas Valve with Coils
  • Lawrence S from Rancho Santa Margarita, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
10 of 15 people found this instruction helpful.