All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
My icemaker started leaking water into the catch basin and turning my ice into one big ice burg.
Well folks I put up with an ice burg all summer when I really should have took the time to fix it. You know how it goes though. You get so busy you just put it off. Well don't put this one off because this is just how easy it went. I came home one evening and wanted to make a drink to relax but that big glob of ice was there waiting for me. I took a crewdriver and beat it down so I could pull the catch basin out. Having looked it over for a minute I grabed a nut driver and took three of the screws out that held it in. I unpluged the wire and bingo it was out. Maybe five min. had elasped. After taking the unit out I notice how the non stick surface was coming off of the tray and that explains the black pieces that were getting into my ice. Getting the model number off the back of the fridge and writing it down I went to my trusty lap top and did a quick search for a ice maker for my Jenn Air refrigeraton and blamo...! Part Select came up and I put the part number in their search engine and bingo again there it was, my part. One quick order and in three days it was right there by my door when I got home. Now i'm so excited. I went into the house and didn't even chage out of my dress clothes. Within five minutes it was in. Now I just had to wait for the timer to do it's thing and sure enough, I awoke the next morning to a whole tray of beautiful ice cubes. Wow no more ice burgs. The moral of my story is I spent so much time hacking out that glob of ice and for fifteen minutes of my time, I could have been siping on cold ones by the pool but now old man winter is pressing down on me and I guess a lesson learned was a lesson earned. Fix it!
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
The frost free drain behind the freezer compartment clogged and water collected in the bottom of the freezer and eventually came out the door on the right front of the refrigerator.
The other instructions and the video provided by Parts Direct are pretty good with instructions, but they omit two steps. First, if you have an ice maker, you will need to unplug the connector on the back side of the panel you remove at the back of the refrigerator to access the drain tube. Just unplug it and you can move the removed panel to the side without disconnecting any of the water lines. Second, the instructions say to just reconnect the "bottom end" of the new p-trap drain to the drain pan at the bottom of the refrigerator. They don't tell you there are two places to connect the new p-trap to the drain pan. The original tube/trough connected to the one at the back of the drain pan on the left (viewed from the rear of the refrigerator). At first, it looks like the new p-trap won't reach to it for the connection, but if you look closer, there is another connector to the right of the original one that the p-trap connects to properly. Replacing the drain trough with the new p-trap was actually pretty easy and would only take about a half hour. Add another half hour to give the refrigerator coils a good cleaning as they will need it now that you can reach them. The real time consumer, 3 to 4 hours, is needed to use a hair dryer to melt and clear the ice from the condenser at the back of the freezer so the water can drain. Just take your time and all the ice will eventually melt and drain out so the new p-trap will work properly.
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
I removed the 5/16 inch hex head nuts holding the rear access panel where the power cord was connected. Once removed, I released the Molex plug and ground wire. I connected the new cord, screwed in the ground and installed the rear panel. Having the exact OEM part made the job quick and easy.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
Follow your parts diagram, I removed the nut screw from the light in the refrigerator. Removed the light cover. Removed the temperture control knob. Remove the damper control cover. Slid the light assembly forward. Pulled out old defrost timer, replaced with new one. reversed assembly order.
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
COILS WAS ICING ON REFRIGRATOR SOLID ICED FOUND ENTIRE COILS
CHECK DEFROST THERMOSTAT WITH VOLT OHM METER AND FOUND THERMOSTAT BAD ALSO OHMED OUT HEATER AND HEATER CHECKED OK INSTALLED HEAT SRINK CONNECTORS ON NEW DEFROST THERMOSTAT PUT SYSTEM BACK INTO O PRATION ALSO CHANGED WATER FILTER ON REFERGRATOR SYSTEM WORKING OK AND NO ICING OF COILS THANKS WADE BOYLES
Refrigerator would not cool, while the freezer kept food frozen and the ice maker worked fine. Also, noticed frost build up at the rear of the freezer compartment
First, turned off the circuit breaker. Then: 1. Removed all food, , wire sliding baskets, and the ice bin. 2. Removed ice maker by removing the electrical connector from the socket in the rear panel, removed the single bottom screw with a 1/4” nut driver, loosened the 2 top screws with a 1/4” nut driver, and lifting the unit up and off the 2 loosened screws. 3. Removed the freezer door by loosening the 4 screws( 2 on each side) with a 1/4” nut driver and then lifting the door face off the loosened screws. 4. The next task is to remove the panel at the rear of the freezer compartment: use a flat blade screw driver to compress the side clips that hold the ice maker electrical socket, pushing it into the space behind the rear panel, then removing the rear plastic cover in the center of the rear panel, and finally removing the thermistor cover on the right rear upper corner of the rear panel( separate the thermistor from this piece, threading it through the slot in the top of the plastic cover. Now, the rear panel can be removed by removing the 4 1/4”” hex head screws with the nut driver and gently easing the panel from its position. 5. Now comes the hard part: the defrost thermostat and most of the surrounding “plumbing” was encased in ice. I used a hair dryer to melt the ice, which created an overflow of water drawing into the collection pan; get ready to mop up this water. 6. With ALL the ice melted( this took over an hour), I simply cut the 2 wires, stripped the feed ends, removed the defective unit, clipped the new thermostat to the copper tube where the old unit was clipped, cut excess wire/stripped the new wires and used 2 orange wire nuts to connect each wire. Now all the parts and pieces can be reinstalled in the reverse order