Fridge smelled like something electronic was burning
Removed the back cover of the fridge with it still pluged in. The next time the compressor tried to kick on, a small piece of black plastic next to the black tank caught fire, and then went out. I unpluged the fridge, unpluged the two wires feeding the black box. Then the box unpluged from the tank. I searched on the internet for the part using the model #. It ended up being a overload/ptc or relay. There was a smaller black box attached with I think is some sort of an overload. I unplugged the overload and it plugged right into the new relay I had overnighted. Although the new relay was white (not black) and the plug attachments were in different locations, it work great.
I checked the compressor and it was running. Next I removed the doors amd screws that held the divider strip. Next removed the bottom of the freezer to expose the evaporator fan. Removed the fan and checked it out with volt ohm meter. Discovered the fan motor was out. Ordered new one on line and received thenext delivery day. Insatlled in reverse of disassembly. When I plugged it in everything worked fine. Thanks for the quick delivery. You provided fine service. Sincerely, Joe Sutphen
defrost drain tube freezing up and stopping circulating fan motor
shut down power- removed plastic covering in refrigerator -installed new part- This has been installed for about 1 week and as of today every thing is working fine. This problem would occur about every 1-2months. So I will not really know for sure until some time goes by
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
water leaking from grommet tube assembly at back of fridge
After thawing out freezer pushed water supply tube out from inside freezer diconneted the supply line from the valve assembly by pushing in the bushing with my finger and inserting the new line. Sadly that wasn't the problem!For anyone with the same symptoms of ice building up on your ice maker, to the point where it clogged the water supply line and started leaking from the grommet assembly. The problem is the valve not closing when the ice maker does not need any water. so I ordered a new valve and hopefully that will fix my problem.
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
water line (from the PS304374 Dual Inlet Water Valve) to the ice maker was craked and leaking
1. Removed the back panel of the fridge to get access to the inlet water valve. 2. Removed black poly water line from valve (pull back on white ring where line is attached and pull the line out) 3. Removed the inlet tube from top-back of fridge (where it goes into the ice make). use putty knife to get under the sticky white gasket beneath the black oval housing and pull the tube out form the back of the fridge. 4. Replace the water line with new part taking care to properly seat the line into the the bottom water valve and pushing the water tube into the hole for the ice maker.
Note: Be sure to take off the protective covering from the white - sticky grommet and push to adhere to metal on fridge.
to be safe - use a bit of clear silicone chaulking round the perimeter of the grommet and push to tighly bond the water inlet tube to the fridge.
The reason for this - is that if you do not get a good bond using the white - sticky gormmet alone - you may have the water tube inside the ice maker freeze up.
Also once the new water line is installed be sure to secure the line to the metal back of the fridge - so the line will not move. some fridges come with metal hose clamps to do this - otherwise use duct tape
After shutting off the h2o, I unplugged the refrigerator. Using the nut driver, I removed the cardboard backing. Then I removed the fitting where the inlet line to the ice maker and pried the old tubing from the unit. I then undid the clasp about 1/2 way up the back and removed the section that went through the back to the ice maker. I then reassembled everything and plugged in the refrigerator as well as turning on the water. Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
freezer compartment worked fine but very little cooling going to refrigerator section.
Freezer worked great but no cooling to refrigerator section. Replaced with part ordered. Phillips head screw driver is all that is needed. Very easy to replace, it's plug and play. New part powered up neither the freezer nor the refrigerator. Went back to old part and atleast freezer still works. New part was no good from factory. The replacement part# matched the original. I attempted to contact PartsSelect but there was no response back.
1. I unplugged the refrigerator/ freezer 2. Turned off water supply 3. Removed the screws that held the cardboard skirt in place 4. Unplugged the water tube from the push connect 5. Removed the screws around the water inlet to the ice maker 6. Remove the water fill tube 7. Install new water fill tube and put all the screws and plates back where they go