Old Defrost Timer Noisy During Operation
First I removed the plastic grill (pulled out, no screws) from bottom of refrigerator, then I removed electrical plug & two screws from old timer (timer located on the front inside left lower side of refrigerator). Installed in reverse order.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Our old gasket was shot to hell, so we figured we'd replace it to see if that would solve the problem. We followed the instructions of another customer. We realized it was better if we removed the entire door in order to attach the gasket. That took a little doing, but it was totally the way to go. Miracle of Miracles, the leaking has stopped, the food is super cold, and I couldn't be happier.
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
Two of the end caps of one shelf and one of another were broken
Ordered the pairs of end caps for both the door shelves. The parts arrived the next day. Opened the wrapper slid the end caps on and attached the shelves to the door. Bingo!!! It was that Easy! Done in less than two days and less than $20. It took me some time to figure out if the parts were right though when I searched online.
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.