Models > F45XH24BD0 > Instructions

F45XH24BD0 Frigidaire Refrigerator - Instructions

All Instructions for the F45XH24BD0
61 - 75 of 268
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Water dispenser lever broke.
removed water tray, used a razor blade to brake the seal from the face plate and the fridge, The hardest part was the three screws holding the dispenser face place on where rusted over. I wound up drilling them out. Once the screws removed, a slight lift, the face plate comes right off. I unplugged the cable, and set it aside. Now remove the next three screws, and the dispenser falls forward, (as far as the water line allows) undo the screws leaving the one emplace to hold the ice lever. push up twist. The hard part is getting the new one up and in. just takes a little patients.
Parts Used:
BULB
  • Donald from LANCASTER, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker which was splashing water
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Parts Used:
Refrigerator Ice Maker Assembly
  • John from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bottom Of Ice Maker Was Frosting Over With Ice Crystals.R
Removed four screws at top and two at bottom and pulled ice maker unit out and replaced with the new lever .
Parts Used:
Ice Door Wire
  • william from Snow Hill, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Valve was leaking
First of all I got the part in less than 24 hours without paying any extra shipping, great service.
The part was easy to install, removed 2 screws and 2 plastic water lines, disconenected water line from the sink (turn off water first) and put in new part took less than 30 minutes and is working perfectly.
Parts Used:
Dual Outlet Water Valve
  • Jerry from Beaufort, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coils freezing refrigerator not cooling
The defrost timer is located under the freezer side behind the lower plastic cover. Very simple, just 2 screws and a plug, and your done.

The thermostat requires removing the lower drawers in the freezer and unscrew the back side of the rails and let them hang over to get access to the lower cover on the back of the freezer. Once the panel is off you will be able to see the thermostat. From there you just remove the thermostat from the clip, cut the 2 wires, splice in the new thermostat and re install using the new clip and your done!!

This was my first time and it was really simple. I had a local repair shop quote me $375.00 . I did it myself for under 50.00 shipped to my door..
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Else from Plant City, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer defrost would melt the food
Looked up similar problems and found it to be the defrost timer. All I had to do was remove the plastic portion in the fridge section to get to the old timer. Popped the new one in and put it back together. Works great now. Would have been almost $150 to have a repair company come out and fix it.
Parts Used:
Defrost Timer - 60Hz 120V
  • Joseph from West Allis, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice despenser door would not close, frosting up in side, would not despense ice`
Removed outside cover on door despencer, (4 screws) unplug wire, removed unit from refrig and replace rusted thru wire that holds door shut. It was fairly easy. I actually took it apart twice, once for diagnosis and once for repair after the part arrived.
Parts Used:
Ice Door Wire
  • Richard from Austell, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker went bad
take the ice bin out of freezer. there are 2- 1/4" screws. these screws only need to be loosened a few turns. the ice maker can be slightly lifted up and will come off the screws. unhook the wire harness. take the "L" bracket off the old ice maker and put on the new one. set the new ice maker in. hook up the wire harness. put the new ice maker over the screws, tuck the wires out of the way and pull down into place. tighten the screws.
Parts Used:
Replacement Ice Maker
  • nathan from gillette, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Parts Used:
Light Bulb
  • ANGELA from MEBANE, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker ffss2614qpo
Looked it up on how to, follow the video
. Very easy 1-2-3 it was out and new one in..........??.
Parts Used:
Refrigerator Ice Maker Assembly
  • Dante from SOUTHOLD, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker leaking, then would'nt shut off.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
Parts Used:
Replacement Ice Maker
  • Terry from KEYSTONE, IN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive great stripped for ice eject. Heater bad
Loosened the 2 bolts 4 turns where it mounts inside the freezer. Lift maker off the bolts unplug 1 plug. Reverse to install.
Parts Used:
Refrigerator Ice Maker Assembly
  • Danny from PUEBLO, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing Icemaker
Pull refrigerator from wall and disconnect the water line and unplug the power.

On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.

Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..

Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.

Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.

In about an hour you should have ice filling the bin. Enjoy!
Parts Used:
Refrigerator Ice Maker Assembly
  • Richard Allen from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from VOLANT, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
sometimes it would go into defrost and would not go back to cooling.
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
Parts Used:
Defrost Timer - 60Hz 120V
  • Henry D from PETERSTOWN, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the F45XH24BD0
61 - 75 of 268