ice maker quit making ice
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
Parts Used:
Replacement Ice Maker
  • Barry from Middletown, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
my shelf supports broke
I pulled out the old pieces and poped what I couldn't into the foam insulation behind the support. Then I placed the new piece in the hole and popped the plastic pin to seat the support. bang. the only problem I had was knowing if it was the right part by the picture. The little pin that had to be pushed through kinda threw me.
Parts Used:
Crisper Drawer Cover Support
  • michael from hanford, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
Parts Used:
Light Bulb
  • Lise from CEDAR GROVE, NJ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original Ice Maker quit working.
Loosened the 2 screws a little so that it would slide up and off then unplugged the wire harness.
Installed the new one in reverse order and works like a champ.
Parts Used:
Replacement Ice Maker
  • Gary from Azle, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
my old ice maker leaked at the bottom
it was really easy changing the ice maker. the only trouble i had was the wiring. it was very stiff and hard to route. it did not work at first but that was my fault did not have the connector plugged in all the way.since then it works great.
Parts Used:
Replacement Ice Maker
  • harry from terre haute, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils freezing up and refrigerator would get warm
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Success! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Parts Used:
Defrost Thermostat
  • Richard from Scranton, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosted up
Removed old thermostat and replaced. really easy.
Parts Used:
Defrost Thermostat
  • Gregg from Mohnton, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working (Very oxidized residue)
I removed the old ice maker and unplugged the cable. Screwed in the new one with a 1/4 nut driver at the 2 mounting screws, plugged cable in. Checked ice maker with a small level before final. All Ok and after night I had Ice and it has been working great since.
Parts Used:
Replacement Ice Maker
  • Robert from Woodstock, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I replaced the icemaker
I removed the two screws and unplugged it. I then attached the pigtail to the appliance, then to the fridge. I had to push the excess wire harness into the hole in the back. It took a few minutes to move the rest of the harness out of the way by curving it upward and securing it with a nylon tie.I ordered the ice maker from Part Select on Sunday night and it arrived at 8:32 Tuesday morning, THANK YOU! I ordered very simple weed cutter parts from Sears a week ago and they haven't even shipped yet!
Parts Used:
Replacement Ice Maker
  • Michele from Smithfield, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Parts Used:
Defrost Thermostat
  • Arthur from Lithonia, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water did not reach ice maker
We replaced the water control valve. We took the old one out and put the new one in. We primed it and then it took off.
Parts Used:
Dual Outlet Water Valve
  • Carolyn from Crab Orchard, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would not defrost
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
Parts Used:
Defrost Thermostat
  • Fernando from La Grange, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Parts Used:
Defrost Timer - 60Hz 120V
  • Steve from Cedar Park, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frequent dripping on floor and no cycling of compressor
After posting the specific symptoms and getting feedback, I had narrowed the cause to two linked parts. I ordered both intending to replace first one, then the other as needed. With parts in hand, I pulled off the freezer control knob, used a nut driver to remove the two panel securing screws (behind the face, against the inner ceiling) and gently dropped the cover down. The control (temp sensor and cold control) is easily accessible as it sits wedged into two slots in the plastic cover. The control must be slightly lifted in order to extract the long sensor that attaches to the control and runs under it and into a plastic sleeve behind the panel (the new control comes with the sensor wrapped in a tight coil and it must be unwound for the install). Removed the three wires noting which color goes where. Used needle-nose pliers to remove the small push-on tabs and removed the control. After starting the new sensor probe into the sleeve re-attached the 3 wires to the new control. Used the original as a model for how to pre-bend the probe for the first 2 inches as it was mildly frustrating to position the unit back correctly. Pushed everything back into place, re-installed the screws and plugged the fridge back in...(you DID unplug it first, right?). Still haven't used the second part (defrost timer), but I expect it to go soon...it is a 17 year old refrigerator, after all.
Parts Used:
Temperature Control Defrost Timer - 60Hz 120V
  • Edward from DELAND, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken crisper holder (bracket)
Removed broke bracket. Installed new bracket (part #100). Now, everything is O-TAY!
Parts Used:
Crisper Drawer Cover Support
  • Charles from LECANTO, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!