Models > ESS22XGMCBB > Instructions

ESS22XGMCBB General Electric Refrigerator - Instructions

All Instructions for the ESS22XGMCBB
61 - 75 of 1826
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
frost builds up in freezer section and refrigerator stops working slowly. manually defrost for 24-48 hours and starts working perfect. Goes through the cycle again after a week.
As advised by the forum just replaced the defrost heater assembly now the refrigerator works perfect. did not have to replace the thermostat.
My nephew had exactly same problem on ge refrigerator - replaced the defrost heater assembly and the problem is solved. Just remove the back panel in the freezer compartment, disconnect the cable, remove the nuts and replace the assemble. It is very simple. Bought both assembly from parts select.com - got next day delivery. they are great. would do business in future.
Parts Used:
Defrost Heater Harness Kit
  • David from West Palm Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
34 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The partion between the tub and dispenser broke
Once I got the correct part, (the expanded view of the icemaker is confusing as it shows the partition at the back of the diagram) I removed the ice dispenser from the tub by removing the screws and disengage the tabs holding the dispenser assembly in the tub. The most difficult step was getting the disenser disengaged from the tub. I used two kitchen knives to wedge between the walls of the tub. It was then easy to remove and replace the broken inside partition and reassemble the dispenser. Works like new.
Parts Used:
Housing Crusher Dispenser
  • Mark from Brandon, MS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
36 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not run.
I found if I would put pressure on one connector on the board the unit would come on. So the board had a short. I ordered it, it came in 24 hours and I installed it and problem was solved.
Parts Used:
Main Electronic Control Board
  • Robert from Battle Creek, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
34 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • James from Greenville, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace broken ice funnel dispenser cradle
Removed outer trim by pulling it carefully out of its clips. Then disengaged the electronic display card by grabing the bottom of the card to disengage the card from the upper clips. I leaned the card forward and disconnected the wire connectors. Removed the 4 screws to take off the frame that contains the funnel. Remove the broken funnel from clips. Note study how the spring is engaged. Note position of the rubber funnel how there is a gap for the water tube. Removed the rubber funnel and attached to new funnel dispenser. Start at one end of the rubber flap and work around engaging the rubber into tabs. Replace the Funnel dispenser back into frame. Make sure the longer wire of the spring sits flat on the plastic frame and that the right elbow of the spring raps around the edge of the funnel. Secured the frame assembly back into the Refig using 4 screws and attached out trim starting withe bottom tabs engaged first.
Parts Used:
Ice Funnel
  • David from Sparks, NV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
53 of 94 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
Parts Used:
Ice Maker
  • Joe from Brentwood, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice cube production stopped; ice cube chute door is seized.
Problem: I have a black colored GE 24.9 cubic inch side-by-side refrigerator, model #GSH25KGMCBB that I purchased new in 2002. The ice cube maker stopped supplying ice cubes and the ice dispenser door stopped operating.

Repair: Unplugged refrigerator first and shut off the house water supply valve. Removed the lower rear access cover and replaced the double solenoid water valve. Icemaker and water dispenser tubing are easily removed by pushing in and holding down the white plastic collar where the tubing is inserted into each port on the valve body; no tools required to release the tubing. Hint: When reconnecting the water outlet tubing, ensure the tube diameter matches the port on the valve body. Insert each tube by hand back into the ports of the valve until they firmly seated.

Removed the control panel by inserting a small screwdriver into the three holes located on the bottom of the control panel body. Removed all of the ice dispenser door hardware and the door solenoid. The door solenoid armature was seized by corrosion. Cleaned off all of the accumulated dirt and mold with a 1:10 ratio solution of bleach and water. Replaced all of the door recess and solenoid valve fasteners with my own stainless steel #4-40 thread, 0.25" long socket head screws for longer life. The installation of the remaining hardware is the reverse of how it was removed.

The installation looks very clean now and $150 later, the ice maker still doesn't produce ice!

Root-cause analysis: I disconnected the ice cube maker water supply line from the double solenoid valve at the rear of the refrigerator and was able to blow air with my mouth straight through the outlet of the water tubing located inside of the freezer compartment; to ensure it wasn't blocked. Verified the water supply valve is not being energized! Turns out that the blinking green LED indicator on the ice cube maker is indicating more than the troubleshooting guide does about that because the white colored insulated conductor in the electrical harness for the ice cube maker is not energizing the solenoid on the water supply valve!

Conclusion: the ice cube maker assembly is next on the list of replacement parts!!
Parts Used:
Torsion-Fit Spring Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper WATER VALVE WITH GUARD Door Recess Retainer Micro Switch SCREW-PKG 12 Dispenser Door Recess Crank Recess Door Spring SCREW
  • Bruce from Mebane, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
Parts Used:
MWF BYPASS
  • Fred from Edgartown, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Parts Used:
Ice Maker
  • Steven from Cave Creek, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Was Not Cold Enough To Keep Food Frozen Or Make Ice
I am a single mom of two with limited funds. I had a repairman come out and find the problem and give an estimate. We were told that it was the evaporator fan motor and and the main control board. The repair would cost $400 and no guarantee. So I checked the cost of parts and it was $200 so for no guarantee I figured why not try it myself and possibly save $200. So I ordered the parts from partselect. Even though I paid the cheapest postage they arrived the next day. So from what I read and saw this would be a piece of cake. Well let me just say if the freezer section was gutted to begin with it might not have been that big of a deal. As it was getting to the top screws of the panel that covers the evaporator fan required the removal of the icemaker and all. I am not a tall woman nor am I a thin woman and fitting my body in that small freezer section was not easy. There were times that I had to have my teenagers reach a long arm in and hold a part up for me. After that I discovered that the fan I had purchased only had 4 wires. The one from my old fan had 6. I discovered that 2 of the wires went to some sort of sensor. Long story short I rigged it. I was able to remove the 2 prongs for the sensor and insert them into the empty holes on the new fan harness. It wasnt easy. I have limited tools too and I wont even get into how I did it. They did not fit the greatest so I used the electrical tape to cover the whole connection. I put the whole thing back together and debated on trying it without putting in the main board but I decided to trust the repairman this time and go for it. Getting to the main board was no big deal. But what disturbed me was the main board I held in my hands did not look exactly like the main board I was about to take out. I watched the video 3 times my how easy it looked. I then read the directions that came with it. It talked about removing a pin and cutting a wire. Well I about had a stroke worrying. I finally found the serial # on my frig and thankfully mine was not on the list. However the directions did still say something about if there wasnt a wire in pin 2 proceed to step 3. Well I had a wire in pin 2. So it was confusing. My serial # wasnt one of the models #'s given but I did have a wire in pin 2. I just took a chance and trusted the serial #'s and ignored the rest of it. I plugged the wires on the new board one at a time. Put the cover back on and prayed as I plugged it in. A soft purr began. It was running. The freezer was around 60 degrees. I put a room thermometer in to make sure it was going down. It kept going down. Around 3 hours after I finished there was a loud noise from the freezer. It had made ice something it had not done in months. I stayed awake most of the night watching and listening to it. It got down in the single digits I was afraid that maybe it would never shut off. It finally shut off as I was making the kids breakfast the next morning. Of course I was worried that it would not restart. So I opened the freezer and fanned in room air. It worked. Since then we have purchased no more dry ice or regular ice. We bought a tub of ice cream and more than one day of school lunch stuff at a time. Bottom line it works. Thanks to everyones post and to partselect for the video. I hope that I never have to do it again though.
Parts Used:
Main Electronic Control Board Evaporator Fan Motor Evaporator Thermistor Clip
  • MARCELLA from FAIRDALE, KY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
39 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker would not dispense cubes or crushed ice
Cause: Failed relays on main circuit board. Fix: Main circuit board replacement: Unplugged refrigerator. Removed 10 screws securing main circuit board metal cover (located on back of refrigerator) using a nutdriver. Disconnected 7 multi-pin electrical connectors from the circuit-board by firmly pulling each connector from the circuitboard sockets using a needlenose plyers. Depressed the small locking prong on each of the 4 plastic circuit board mounting pegs while pulling the board off the mounting pegs.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
Parts Used:
Main Electronic Control Board
  • Jeffrey from Highlands Ranch, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
33 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Dispenser Door Recess Crank Recess Door Spring
  • Victor from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
40 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warm Refrigerator, No door water
Remove the following: lower rails, evap cover, ice maker assembly, attaching hardware for light and evap fan. Follow directions for replacing defrost heater. cut and splice wires for new defrost thermostat, and temperature sensor using adhesive line shrink tube. reassemble. Work like new.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat Drawer Slide Rail - Right Side Drawer Slide Rail - Left Side Temperature Sensor Trim Pan - Right Side
  • William from Garden City, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
43 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Parts Used:
Temperature Sensor
  • Michael from Milton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
30 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Parts Used:
Ice Maker
  • John from Lodi, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ESS22XGMCBB