First I replaced the door gasket as every one else. This cut drips about 30%. I then discoverd that the Rinse Aid circular dispenser cap was opened about half way. I turned the cap tightly clockwise to close and cut drips to 90% total. I czn live with the other 10%,
Unit would only stay on if one was pushing the door
First I removed power to the dishwasher. The inside panel of the dishwasher door is held on with several screws with Phillips heads. Remove those and the panel comes off. There is a silver metal guard that you have to pull off being careful not to tear the insulation that is on the other side. Then there is one hex head screw to take off the handle latch assembly. You remove this assembly and take off the wires to the two switches on each side of the assembly. The replacement part doesn't come with the black plunger that pushes on the switch buttons so you have to remove it from the old assembly. This was the only difficult part, I essentially destroyed the old plastic assembly getting it out. But putting it in the new assembly was easy. Then I attached the wires to the switches in the new part and reassembled everything. Works like a charm now.
pulled out the old gasket, cleaned the area before pressing in the new gasket with my fingers ,I made sure to put it in the same way as the old one. You have no idea how happy I am that this solved the problem.
Two clips holding the adjustable shelf had broken off.
I didn't know how to put in the new one clips until I looked up a picture of them in place, on-line. Once I saw the picture, it was a matter of clipping the new ones in place.
Both door springs corroded and broke. Linkage connectors broke also.
After pulling dishwasher out both springs easily installed using plastic connectors on the bottom left and right sides. Pliars were used to stretch the springs. It took fifteen minutes at most.
I removed the inside door cover, unpluged the accuator, removed the two screws holding the dispenser latch in place. Replaced both the latch and rubber groumet. returned the door to normal operation and verified no leaks was present.
Dishwasher wouldn't start, no power on any setting
Removed door interior, confirmed with tester that power was reaching door cut-off switch, but not power on other side of switch when engaged. Noticed that little switch button frozen in shut position, assumed switch had burned out. Installer new door cut-off switch with new (dual) switch units in place, plugged in unit and it ran perfectly.
I went to take the bottom front panel off and ended up dropping the screw down behind the baseboard and then found that I did not need to take the panel off. The broken end of the float was not obstructing and I was able to just drop the new float in place. I spent more time looking for a replacement screw than any thing else. Ran it and it works fine.