Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
I was looking to see if there was a reason that there was no ice. By luck I removed the cover to the ice maker and found two gears, one of which was damaged. I could see one of the gears had missing teeth. I ordered part to fix problem and received the gear. 10 minutes later, viola! ice maker restarted and ice was falling in a few minutes.
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time. John Moragues
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Vacuumed the area around the compressor, removed the PTC relay switch cover, pried the broken relay switch off the unit with a screw driver and replaced with the new relay switch. Replaced the backing of the refrigerator and tested, within minutes the work was confirmed.
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.