Door would not stay closed
I took the top over off the pivet bracket and used a nut driver to remove the screws on the pivet. Lifted the door off and put on some saw horsess. I revoved the pieces of the old cam on the door by taking out the screw and put the new cam back.
I then drilled out the rivet on the bracket on the door and removed the broken cam. replaced it with the new one and used a screw and nut to replace the rivet. Put the door back and works great now.
Parts Used:
Door Closing Cam
  • Thomas from Boulder, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Right side door (refigerator) would not stay closed
completely removed door, then replaced worn-out cam on bottom of door-simple enough; then removed hinge from bottom of refrigerator; removing old cam required drilling out the rivet that fastened cam to hinge; secured new cam to hinge with small machine screw and nut. This procedure is relatively easy but does require minor mechanical ability and having a small drill and bit set. However, replacing the two cams totally fixed the problem.
Parts Used:
Door Closing Cam
  • Allen from Cheyenne, WY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door dropped when opening and wouldn't stay partially opened
removed top plate and raised the door off. I removed the L bracket from the fridge then noticed the part was rivited onto the L bracket. I cut the rivit and replaced the cam and used a small bolt and nut to sdecure it. Replaced the L bracket, the door, and the upper support. Only problem was the surprise rivit
Parts Used:
Door Closing Cam
  • Eugene from Macedon, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door wouldn't close by itself. Cam part found on floor.
I removed two screws at the top of the door, lifted the door off. I got lucky: the broken cam was the one on the door (easy to remove), not the one on the body of the refrigerator (tough to remove).
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
Parts Used:
Door Closing Cam
  • Peter from Springfield, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge door did no close and was out of alignment
Followed previous poster's steps. Replacement of door closing cams took 35 minutes. Make sure you buy 2 cams for each door.
Parts Used:
Door Closing Cam
  • William from Washington, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door was uneven and wouldn't close tight
removed the door, installed the cam riser, and reattached the door. It took longer to remove the contents in the door than it did to install the cam riser.
Parts Used:
Door Closing Cam
  • gregory from ellerslie, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door closing cam worn out
Removed refrigerator door and replaced bottom door pivot with the included mating cam and the door closing cam on the bottom of the door.

I didn't know that there were two mating cams and only ordered the door closing cam which I read online was the problem. It was the number one part on the part select list. The number two part was a kit including the door closing cam and the pivot with mating cam attached. It would have been helpful if there had been some notes that said check condition of both cams before ordering the part. So I have a spare door closing cam and paid an extra $19 including $8 shipping which negated a return.

The repair is easy - getting the right parts the first time is the trick.
Parts Used:
Door Closing Cam
  • Edward from Grand Blanc, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would hang up half way closed
Replaced both upper and lower cam's. Removed door from refrigerator, removed bolts on door cam on bottom of main door and replaced cam, then removed bolts from door hinge assembly, drilled out rivet holding on cam, replaced with new cam and re-riveted.
Parts Used:
Door Closing Cam
  • DAVID from NEWPORT, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Problem closing door, would not shut easily.
My wife and I gave an old, but really good refergerator to our son (a Major in the Army). Upon taking it into his house he had to remove the doors of the refergerator. While he put the doors he lost the "cam" for the door, making if difficult to close (actually had to lift the door up and then close it). I ordered the replacement part, and unless I am mistaken, it arrived the same day. I still cannot figure out how this happened, but it was great!!
Parts Used:
Door Closing Cam
  • Michael from Burmingham, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
plastic cams on the door broke so the door wouldn't close
Why don't they just tell you that you have to buy 2 cams. I have now replaced the cams on both doors. The other door broke about 4 years ago. Fortunately the first time I read the user commetns or I would've bought just one. It is a quick easy fix. The longest step is drilling out and replacing the rivet. Everything else is done with a nut driver.
Parts Used:
Door Closing Cam
  • david from pocatello, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken cam riser
Thought I would only need one when I looked at the picture of the parts. Decided to order two just in case and after taking it apart both were broken. Needed two.
Took the top door bracket off and lifted the door off of the bottom bracket. Re-assembled cams, put a little white grease on all moving parts, placed the door into bottom bracket and installed top bracket. Adjusted top bracket to make door line up with edge of refrigerator and all is well.
Parts Used:
Door Closing Cam
  • Robert from Ipava, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The rails holding the vegetable drawer were broken
It was a trivial repair job -- just removed the Philips-head screws holding in the broken rails, and screwed in the new ones. (I also took the opportunity to scrub the bottom walls and floor of the fridge.) I'm just glad that PartSelect had the parts available, and that it was so easy to locate them!
Parts Used:
Pan Slide - Left Side Pan Slide - Right Side
  • Lewis from Salt Lake City, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Closing Cam broke
The bottom of the door was 5 " off the floor. A 2x4 block and a 4x4 block were pushed under the door and supported it while the water line was disconnected the hinge removed and the cam replaced. It was a simple fix and reading other people's experience made the repair so much easier.
Parts Used:
Door Closing Cam
  • Charles M from Concord, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door won't close
This my second time to do it after 8 years. Took 10 minutes.
1 Remove all the contents on the side door
2 Remove the 2 bolts on top connecting the door to the refrigarator
3 Lift and remove the door up and put it the side
4 Clean and remove the old door closing cam put the new one
5 Door ref is fixed
Parts Used:
Door Closing Cam
  • Robert from Darien, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Slots on the new Hinge did not line up on the refridgerator
I popped the rivet of the new hinge I received, removed the plastic bushing and installed it on my old hinge - this was the part that went bad on my old hinge. I re-installed my old hinge with the new bushing, problem solved
Parts Used:
Door Hinge and Closing Cam
  • Michael from Chatsworth, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!