No leveling legs
Ordered the leveling bolts, very fast shipping, parts correct as shown. Purchased a condo by the shore, frige had no levelers, they went in smoothly & was done in no time. Steve
had to saw off the shaft to get the yoke off and tap the holes for the 8/32 screws. all holes should have been tapped by the factory. Other than these problems, everything else went pretty good.
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case... - check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side - inspect that the fan in the freezer side is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit - remove all goods from freezer and fridge - remove freezer side racks - remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place) - allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun) - disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram) - if you get a very high resistance reading, the heater element is likely broken. if so... -- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements) -- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass) -- if you see nothing, remove them anyway (since high reading) and check connectors -- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER. - get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F. - if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer -- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller -- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Found a tip online that said to check the resistance of the defrost coil, when I had none I knew the coils had burned out. Before pulling the old coil out I tied on some long pieces of string as was suggested, that made things go very quick! The hardest part was reaching to the back of the narrow freezer space, but fortunately I have long arms. So far all is working well, and I have a great deal of satisfaction knowing I did the repair myself!
First I removed all the screws from the back cover. 2nd removed fan nut and fan blade 3rd removed fan bracket 4th I traced wire to the condenser and disconnected wires from wire nuts. Installed existing fan brackets to new motor kit then reconnected wire nuts to new motor cord Reinstalled fan nut and blade, reinstalled cover, plugged it in and BAM .WORKS PERF!
I pulled the drive ring off of the icemaker and replaced it with the new part. Saved a $150 service call plus cost of part. It cost me a little over $11.00 and a repairman probably would have charged $30.
Just took old ice tray out and put new one right in place in less than 30 seconds. I am very pleased with how fast the tray arrived after being ordered. if only everything ordered could be made this simple. You are a great company to deal with.
Ice would not come out of try completely due to age and residue buildup
After trying to clean and use chemicles to remove residue, I found that it would not work. Ice would build up in tray causing an overflow in the fill process. this would freeze cubes in tray below causing dispenser not to work properly, New tray seemed to solve the problem. Removed old and installed new
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Removed 6 screws to get at broken part. Had to remember the disassembly sequence to properly reassemble. The whole process was relatively simple. I saved about $125 which would have been the cost of a repairman coming to the house.
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Turn off refrig water supply, remove cardboard rear lower cover, disconnect two plastic lines (one for icemaker, the other for in-the-door water dispenser) and one copper fitting (supply line). Replace valve (mounted with one screw), reconnect, test for leaks.
The valve I was so sure was bad wasn't, replacing it didn't solve my problem. Turned out to be a frozen up icermaker water feed tube at the top rear of the refrig. The Fix: heat a metal rod of appropriate size in boiling water or with a hair dryer, poke it gently up into the water drop tube (sticks out just above the rear of the icemaker) from the inside and melt out the ice plug. Be sure to test this tube if you have the same problem, you should be able to disconnect the line on back of the refrig and blow air through the tube if it's clear. Saved the valve anyway for a spare.