Broken Crisper Rail
Removed the drawers and shelf unit above the shelves. Installed the new rail and put the shelf unit and drawers back in. Less than 5 minute repair. Very fast delivery of part and reasonable pricing.
Turn water and refrigerator off, use hair to thaw the ice maker filler tube, then remove the filler tube inside the freezer. Next remove the water supply line cover plate in back of the refrigerator. Now remove the speed clip at the white pvc elbow and pull out the supply line. Next, grasp the pvc elbow with pliers and pull hard to remove. The new filler tube is a 1 piece design (filler tube and elbow combined) and needs to be cut to the proper length. Mark it inside the freezer, remove it and cut to length. Now coat the outside flange with caulk or PU glue and snap into the opening. Put the speed clip on the elbow first and center it. Ensure that the spreader insert is in place in the plastic tube, then slide the supply line into the elbow untill completely engaged. Replace cover.
Clicking noise every 1 minute - Refrigerator ran continuously
unplug Ref. and on back of Ref., take back panel off to locate compressor. Attached to the compressor are 2 small parts, secured to the Ref. w/ a small clip. Remove the clip w/ a pair of plyers. Remove the Capacitor (white plastic electric part)form the Compressor - the black overload relay will come off with it. Plug the new relay in to the Capactor. Locate the two wires (used to connect the Ref. to the Capacitor) from the Ref, unplug them from the old Capacitor/Relay and plug them in to the new part(s). Plug the new parts back in to the Compressor. Reinstall the the small metal clip that holds the Capacitor/Relay in place. Plug Ref. back in - if no noise, parts have worked (allow 5+ mintues to test).
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Found the coils in the freezer frosted up and no cold air getting to the refrig compartment. I first replaced the defrost timer but should have checked with a volt meter as it turned out that it was a thermostat on the coils in the freezer that was faulty, it actually had a visable defect, it was bulged out. I think that this thermostat prevents the defrost heater from over heating the coils. Replaced the defrost timer an this thermostat and all is good now.
I used board levers to do one side at a time.Kinda tricky, but you can hoist up fridge high enough to replace wheels. take your time think it out and be safe . Make sure you use saftey boards to support load to protect yourself==good luck A small mirror may help to see how the rollers alien in the supports.
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.
I had already removed the old ice maker in order to get the modle number.
I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!
The part was an exact match to the old one and the instructions from your website were all I needed to complete this repair. My wife thinks I am somewhat of an appliance genius now. Could not have done it without you...thanks
The refrigerator quit cooling and the compressor would click on and off
I took off the faceplate on the back to access the compressor and took off the overload relay switch from the compressor. The overload fit on the compressor correctly. The top quick connect did not fit on the overload so I had to cut the quick connect off and replace the wires with correct size clamps and replace. It has been working fine.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.