Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
The door seals arrived in good condition, I followed the instruction and unpacked the door seals and straighten them out on the floor. I left them over night to climates. First I empty all the door compartments of food. I then used socket driver and loosened all the hex nut screws around the door. Do not remove the screws. Removed the door seal by pulling it out of the door seal clamp. Once removed clean the door seal clamp and door. Now start at the top and put the door seal into the top door seal clamp. Then work on both sides of the door pushing the seal into the clamp. Finally stretch the seal and insert the bottom section into the door seal clamp. Check and make sure the seal is properly installed around the door seal clamp and the fit is even. Start at the bottom and tighten the bottom screws. Then start tightening the sides and finally the top screws. Make sure there are no wrinkles. If there is undo the screws and reposition the door seal. This is an easy install but takes about 2 hours to do.
Remove two screws from top door hinge. Remove door from unit Remove old broken plastic cam 1 screw Replace new door cam tighten 1 screw Reinstall door and top hinge screws.
Super easy - emptied door of all food, unscrewed bracket from top of door, lifted door off and set aside. Broken cam removed, new one screwed in, and lubed with some Vaseline. Set door back in new cam, screwed bracket into the top, and good to go. I was kinda worried about shopping from PartSelect since I had never heard about them, but the part was here in less than 2 days. Pretty awesome little company.
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
took old socket out, ordered replacement part, dual socket no longer available. Turn off power to appliance, attach new single light socket, screw light socket and light socket holder back into place. Turned on power and it worked. No instructions included in packet, attached wrong first time, blew fuse, attached socket a different way, and it worked.
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Removed the door by taking 3 screws out of the top and lifting straight up, then replaced with the new parts and very easily replaced the door, worked ike a charm, if i didn't know any better it was like factory new
The door made a loud noise on opening and closing.
Emptied the door. Removed the door, top bolts first. Lifted out the door. Installed new cam at the bottom. Set the door back in place. Bolted the top hinge back on. Smooth!
The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.