Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.
Parts Used:
Dual Inlet Water Valve Ice Dispenser Rear Helix
  • Osvaldo from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Parts Used:
Dual Inlet Water Valve
  • Eric from Rose Hill, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Todd from Saint Paul, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Parts Used:
Defrost Timer
  • Bill from Columbiana, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken gear
Removed old gear and tapped the replacement on.
Parts Used:
Icemaker Motor Gear
  • D.H. from Mulberry, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Parts Used:
Condenser Fan Motor - 115V
  • donald from opelousas, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Parts Used:
Defrost Timer
  • Hop from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Timothy from Orange Park, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Parts Used:
Evaporator Fan Blade Kit
  • John from Cumberland, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My ice maker quit making ice.
I removed the maker from the freezer, three phillps head screws, I pulled off the white plastic cover and found the top (small) gear had poped out, after carefull inspection, I notice two missing teeth. I ordered a new gear from ParstSelect re-installed and with in two days my ice maker was working like new. I estimate I saved myself seveal hundred dollars, my wife wanted to call a service professional or worse buy a new refrigerator freezer. Thanks PartSelect!
Parts Used:
Icemaker Motor Gear
  • Steve from Louisville, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
rusty ice maker
removed old parts and installed new. went smooth
Parts Used:
Auger and Front Helix Kit
  • Dean from Park Ridge, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not shut off
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Parts Used:
Icemaker Switch
  • Jack from Bloomington, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator water dispenser tube (5/16"OD) broken at the back by valve
Tube was too short so I used the union to attach additional tubing to reach the valve at the lower rear of refrigerator
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Peter from Marietta, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door wouldn't stay closed; fridge alarm went off constantly
I removed the door from the fridge by taking off the screws that held the top plate on. I then removed the old broken cam from the door and the old hinge pin on the fridge and replaced them with new parts. I then put the door back on, screwed the top plate of the door into the top of the fridge, and with a few minor alignment adjustments with the freezer door, I was done.
Parts Used:
Cam Riser Ice Storage Door Bottom Hinge Pin and Cam Assembly
  • Ralph from Pagosa Springs, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would not defrost
When it was discovered there was a cooling problem in the refrigerator, I went to parts select web site and went through the troubleshooting section. Then I tested the defrost timer and the defrost element as directed by the web site. I then found out doing this, that is was the defrost timer. I ordered the part online and it was delivered THE NEXT DAY! I removed the bottom panel of the fridge, removed the screw holding the old timer, removed the wires, and reversed the procedure to install the new one. It has been 1 week, and everything is working great. Thank you PartSelect.
I have since then recommended you to a relative who was having the same problem. Thanks again.
Parts Used:
Defrost Timer
  • Thomas from Dresden, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!