The old Solenoid was rusted and made a loud noise, also kept the trap door open.
First I removed the face plate by lightly prying . Once removed noticed 4 screws. Removing the screws allows you to gain access to the two plugs, one for the solenoid and the other for the switch that energizes the solenoid . Unplug the connectors and carefully lower the piece enough to reach the 3 screws that hold the solenoid in place. The 4th screw in the center at the bottom of the solenoid is the ground wire. If it is rusted like mine was just re-attatch it to one of the solenoids holding screw. It must be grounded! Just re-assemble, just dont forget to replug the connectors. Also a little hint, If you open the freezer door a little you wont trigger the solenoid.
This seems to be a design problem because I have to replace this part about every other year since we bought it. I tried to talk to GE but all they want to do is send a service man out to replace the part for about 100.00, But I do it for around 15.00. I just think they should find out why the rubbe
The repair is easy, just pop the grill off around the ice and water door, then there are 4 screwws to take out so the touch pad can be moved out of the way to unsnap the old door assm. and snap in the new one and wait about a year and a hald to order another one!!!!!
Freezer would ice up and refrigerator stop cooling
First i unpluged the power then cleaned everything out of freezer and removed all the drawers and racks them removed the 2 screws at bottem of freezerand removed panel then removed 4 screws on the bulbs and unpluged the wire and took off the sensor and replaced with new one put everthing back. Then on the top of refigerator side on the top behind the adjuster is the defrost timer pulled handle out and off removed plastic shield and removed 2 screws and unplug the timer and change it then put everything back and pluged back in and everything worked in a few minutes
This is a sibe-by-side refrigerator/freezer that needed a new lower hinge set for the fridge door.
First I removed everything from inside the fridge door, closed it, then loosened the top hinge bolts with an 8mm socket on a 1/4-inch ratchet. Using an 8mm nutdriver, I removed one bolt and loosed the other just far enough to be able to lift the hinge and swing it out of the way. (These bolts are long. The nutdriver is faster than the ratchet but you need a ratchet or a wrench to first break them loose.) Then I just lifted the door off the bottom hinge and set it aside.
The plastic lower front grill was covering the lower hinge but that grill is just held at the ends by spring clamps -- popped off easily so I could get to the hinge bolts. Again, 8mm bolts, just remove & replace hinge. I also had to replace the upper half of the door closer cam, which is screwed to the bottom of the door, being careful that the holes lined up: cam, shim, door holes.
Now the tricky part was lifitng the door back on the lower hinge. (It helps to have an assistant at the bottom to locate the hole for you.) Once the door was up, I swung the top hinge over, ran the two bolts in finger tight with my nutdriver, checked & adjusted the spacing* of the fridge door and tightened the bolts. This was all very easy! (*^_^*)
*On a side-by-side, you'll want the door to be straight up & down with a consistent gap top to bottom with the freezer door. The hinge has some slack for adjustment by positioning the door, then tightening the bolts. You'll see what I mean.
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.
Replaced several things: evaporator fan motor, defrost heater element & defrost timer. The motor was the key problem but did the other repairs because they are common failures and are easy to replace and are not that expensive. Changing the motor was tedious because of tight access to it. Took about 2 hrs for me. Fan is working properly but not have a problem with water to ice maker not shutting off. I'm researching that problem. (I replace the water valve 2 hrs ago. That was a simple task - took 15 mins.)
1) I removed the icemaker and placed on work table. 2) I pried the front plastic cover from the control box to expose the front base. 3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base 4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.