Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Parts Used:
Refrigerator Door Switch
  • Antonio from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator had shut down
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Parts Used:
Defrost Timer
  • Ronald from Martinsville, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Parts Used:
Refrigerator Door Switch
  • Duncan from Metairie, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Parts Used:
Water Tube Kit
  • Monica from EDMOND, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Parts Used:
Defrost Timer
  • Dana from Canyon Lake, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Parts Used:
Condenser Fan Motor Kit
  • Ernie from Windsor, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Parts Used:
Defrost Timer
  • John from Redmond, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Parts Used:
Defrost Timer
  • Gerald from Orangeburg, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Parts Used:
Light Bulb - 40W
  • Carl from RIVERSIDE, CA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light blew out
change light bulbs
Parts Used:
Light Bulb - 120V 25W
  • KELVIN from SOUTHFIELD, MI
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 2599IW
31 - 45 of 170