burned out Evaporator Fan Motor
simply removed wires from the old motor and gently lifted it out by by the metal clips - put the old bracket on the new motor, snapped on the new fan, replaced the wires, reinstalled the shield. All done in about 15 min.
Parts Used:
Evaporator Fan Motor - 120V 60Hz Evaporator Fan Blade
  • Robert from Surprise, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor quit working
Really simple clear instructions with photos. With this the repair was quick and easy simply remove the bad relay and replace with the correct one. Great delivery time with terrific instructions.
Parts Used:
Compressor Start Device Kit
  • Harry and Janet from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Crisper Drawer
This company is WONDERFUL! I ordered the wrong drawer the first time, but their return process was a snap and the correct drawer arrived the next day. It's great to know that there is someone out there with just about every part you'll need for about any appliance that is truly customer friendly.
Parts Used:
Refrigerator Crisper Drawer with Humidity Control
  • Jennifer from Salvisa, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer wouldn't freeze and the refrigerator wouldn't refrigerate.
Same as everybody else on this post. Real easy. Actually, I just wish I would have done it sooner.
Parts Used:
Evaporator Fan Motor - 120V 60Hz
  • Leandro from Baldwin Park, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit cooling at all.
I removed the cover for the lower part of the refrigerator to inspect the wiring and motor. I removed the switch and removed the wiring from it. The wiring just plugs in. When the new switch arrived, I just reinstalled it to the side of the motor and the refrigerator has been working fine ever since.
Parts Used:
Compressor Start Device Kit
  • Eddie from Ocean Springs, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
16 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit refrigerating
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Parts Used:
Defrost Timer
  • William from Hudson, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Parts Used:
Defrost Timer
  • David from Arnold, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bad door gasket
watched video. Very easy
Parts Used:
Fresh Food Door Gasket
  • William from Palm Coast, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old, cracked freezer door gasket
This is in a rental house; Refrigerator/freezer has been off for a few weeks so just opened the freezer door and used screwdriver to pry out one corner then pliers to grab and pull old gasket (seal) off. Had the new one laid out overnight to relax it; placed one corner on and then the opposite corner then repeated the other two corners. Positioned the keeper edge plastic all of the way around to place the gasket in the door. Closed the door to check the seal and plugged unit back in. Waited and then checked air temp with hand held IR temp gauge. All checked good, no cold spots anywhere. Piece of cake!
Parts Used:
Freezer Door Gasket - White
  • Ken from ALBANY, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rattling noise in beind freezer compartment
remove shelves in freezer compartment incl.holders(slide up to remove)
Remove lamp/shield
Remove panel (six phillips screws)
disconnect motor
pull off fan blade
squeeze bracket holding motor to remove
remove motor.
Re-assemble (in reverse)
Parts Used:
Evaporator Fan Motor - 120V 60Hz Evaporator Fan Blade
  • Herman from Cottonwood, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor not running
found power up to current relay but not to compressor. removed the old current relay and installed the new relay and the compressor started running and the refrigerator works fine now.
Parts Used:
Compressor Start Device Kit
  • james from islamorada, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from under refrigerator.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
Parts Used:
Evaporator Drip Tray
  • Ronald from DELRAN, NJ
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Suspected fan failure
I pulled the refer from the wall, disconnected the power and removed the cardboard cover at the base. Using a vacuum and compressed air, I cleaned it thoroughly.
I used a screwdriver to lift the locking tab on the 3-wire connector and removed it. The best way to get the three bolts off was with a 1/4" drive ratchet and go to the std nutdriver handle when they were loose. The fan came out carefully with the blade. I removed the blade nut with flat nosed pliers, cleaned it and placed it on the new motor. I replaced the motor and installed the screws. On a do-over I would install onew screw in each hole at least halfway to get the threads started/ threaded. After that the connector slipped in and I spun the blade to check for interference. The blades can be slightly bent, but use of nut tension can also slightly adjust fan alignment as it's tight to the housing.
That's it
Parts Used:
Condenser Fan Motor
  • Don from Oregon City, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No-Refrigeration
Read the instructions that came with the relay/overload.

Determined wich of the relays and overloads in the kit supplied was needed on the refrigerator.

removed the old relay and capacitor.

Simply installed the new parts .

Back in business.

Thanks for the quick delivery.
Parts Used:
Compressor Start Device Kit Capacitor
  • Joseph from Red Bank, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
18 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Parts Used:
Defrost Timer
  • Thomas from Pottstown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10641512100
76 - 90 of 707