Arnold J Steele
January 21, 2018
Timer & clock working, temp & controll panel works fine. Problem no heat condition, i heard a pop, then it stop heating. I am going to check my micro switches with a ohm meter for nc and no of the switches, buti need to know something? The unite is 9 years old never any problems, but if i need a matnetron? Should i change the capacitor & diode also because they are all the same age. I t's been a long a time, i mostly deal with tv,s & computers. Thank you for listening to me a steele
For model number FGMV185KFA
Hi Arnold,
Thank you for your question. If there is nothing wrong with the capacitor or the diode, then I would just replace the magnetron. To verify if you need to replace the diode and the capacitor you will need to check the parts out. I hope this helps. Thank you and have a great day!