Quick Question!

Have you ever purchased from PartSelect.com before?

1483583-1-S-GE-WR62X10055        -Dispenser Door Solenoid Assembly
1483583-1-S-GE-WR62X10055        -Dispenser Door Solenoid Assembly 1483583-2-S-GE-WR62X10055        -Dispenser Door Solenoid Assembly 1483583-3-S-GE-WR62X10055        -Dispenser Door Solenoid Assembly https://www.partselect.com/Schematics/GE/00120714i01.gif

Dispenser Door Solenoid Assembly

Your Price

$41.11
Order within the next 9 hrs and your part ships today!
Get this part fast. Average delivery time via standard shipping: 1.8 days.

PartSelect Number PS1483583
Manufacturer Part Number WR62X10055
Manufactured by GE

This part is a possible option when ice door won't open or shut properly or when water is not dispensing.

This part works with the following brands: General Electric, Hotpoint.

This part works with the following products: Refrigerator.

This part fixes the following symptoms:

  • Ice maker won’t dispense ice.
  • Not dispensing water.
  • Door Sweating.
  • Door won’t open or close.
  • Leaking.
  • Freezer section too warm.
  • Ice maker not making ice.
  • Frost buildup.
  • Freezer not defrosting.

Videos For installing this part.

Questions & Answers

Ask our experts a question on this part and we'll respond as soon as we can.

Most Helpful

Question:

How does the door solenoid assembly work . I replaced the flapper because it didn't close properly. Now it sometimes closes. Does the solenoid operate the flapper. Do l need a new spring for the flapper assembly? Almost hopeless help.

Robert for model number GSS25QGMDWW
Answer:

Hi Robert, Thank you for the question. Yes the solenoid is what controls the flapper and opens and closes it when dispensing ice. Unless you can see physical damage or wear to the spring it can be reused with the new flapper and solenoid. Hope this helps!

5 people found this helpful.
Question:

My refrigerator does not dispense ice or water. It makes plenty of ice, but does not dispense. Could this be the problem with part number ps 1483583, dispenser door solenoid, or ps 1483583, micro switch? Or something else? What do you suggest? I don't want to order more parts than i need.

Robert for model number ZFSB26DNDSS
Answer:

Hi Robert, Thank you for your inquiry. It actually could be either of those parts. What I would suggest is that you test them with a multi-meter and see if either of them are malfunctioning. Usually it is more likely that the dispenser solenoid is the problem, however you can test them to make sure. I hope this helps!

3 people found this helpful.
Question:

Will not dispense water.

johnny for model number HSM25GFRASA
Answer:

Hello Johnny, thank you for contacting us. It is possible that it could be the dispenser solenoid. You also may want to check the inlet water valve as well. Hope this helps!

3 people found this helpful.
Question:

I can only get crushed ice from the door dispenser.

latorius mccray for model number gss20Ietabb
Answer:

Hi Latorius, Thank you for the great question.Try to pull your ice bin out and check the opening where the gold or brass colored rod enter. There is a solenoid part number PS1483583 inside that should actuate and move the bucket arm in order to dispense cubes. Stick your finger in there and to get it to drop down. The solenoid may be damaged, or just frozen in place. Once it drops down leave the freezer door open, actuate the door switch with your finger, while pressing the ice lever in the dispenser. Make sure you have selected cube. If the solenoid is working will go up then back down when you release the lever. If not, then you will need to remove the housing and see if it is full of frost. The solenoid shaft must move freely in order to work properly. They can also rust with time and prevent the free movement. Hope this helps!

1 person found this helpful.

Most Recent

Question:

Can the dispenser door solenoid allow for normal ice dispensing without dispensing water? All other parts seem to be functioning properly. Ice without issue, when water line is disconnected before freezer door water will dispense there when hitting the ice funnel, however water will not flow thru freezer door and exit at the dispenser.

Josh for model number GSH25JSDBSS
Answer:

Hi Josh, Thank you for your inquiry. There are some parts that you will need to check to see which one is causing the issue. You will need to check the water inlet valve, the dispenser door solenoid assembly, the micro switch and the union connector. I hope this helps. Thank you and have a great day!

Question:

The door solenoid functions normally on my fridge when dispensing ice, however it will not dispense water. If this part malfunctions can it do one and not the other? I am getting water past the water inlet valve without issue because if i unhook the water line connection before the freezer door water will dispense there when the lever is activated.

Josh for model number GSH25JSDBSS
Answer:

Hi Josh, Thank you for your inquiry. There are some parts that you will need to check to see which one is causing the issue. You will need to check the the water inlet valve, the dispenser door solenoid assembly, the micro switch, the union connector, the ice funnel and the dispenser housing shield. I hope this helps. Thank you and have a great day!

Question:

I am unable to remove plastic piece covering the chute, giving me access to the flap and solenoid. I have removed all 4 screws.The bottom right corner seems to be caught on something. 3 other corners are all loose. There is a light there for water dispenser, is this the problem?

Robin for model number GSH25ISXLSS
Answer:

Hi Robin, Thank you for the question. Watching the video for the solenoid I am showing the after the screws are removed the housing should come right off. Here is a link to the video you might find helpful. Hope this helps! https://www.youtube.com/watch?v=z_s7GJsQkr0

Question:

Have a small water leak at the water dispenser. When we close the valve a little water will continue to leak.

Russell for model number GCL22QGTESV
Answer:

Hi Russell, Thank you for your inquiry. That could just be the water that is still in the line. I would suggest testing your water inlet valve to see if it is working correctly. Otherwise you might have to look at your water line and see if there is a leak somewhere. Good luck with your repair.

1 person found this helpful.

Installation Instructions Provided by PartSelect customers like you.

Average Repair Rating: 3.9 / 5.0, 93 reviews What's this?
 

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: Less than 15 mins
Tools: Screw drivers
Customer: Anthony from Clarksburg, NJ

Ice flapper door not closing

Removing the trim ring around the control panel is the hard part. Be sure to watch the video on how this is done.
Follow the video instructions on how to remove the solenoid and you will not have any trouble.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: ROBERT from VENICE, FL

Ice flapper wouldn't close

Used ice pick on bottom of water/ice cover plate to pop it loose. Removed 4 phillips head screws to gain access to the solenoid. Removed and replaced solenoid. Reinstalled parts removed to gain access to the solenoid.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: Less than 15 mins
Tools: Screw drivers
Customer: Rebecca from Prospect, KY

Flapper for the ice dispenser would not close completely allowing frost to build up in the freezer ice dispensing compartment

I watched the video explaining how to do this and it was a snap. MY PROBLEM WAS COMPLETELY SOLVED. Partselect.com is a must for my household. I couldn't be happier!!!!!

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: Gregory from Simi Valley, CA

The ice-maker flapper door stays open slightly.

I watched the video on this site and read the comments here. Everything went as stated. I simply removed the front cover from the door, carefully pushing in the two plastic dimples to release the plastic piece. I used a very small screwdriver to get in the holes and pushed carefully while gently prying on the piece. It popped right out. I then carefully removed the three wire harnesses from the back of the cover. I then removed the four phillips screws that hold the cup pushing assembly on. I found this piece to be rather dirty/black moldy. I spent more time cleaning this with a toothbrush and soaking it than I did with the total repair of the solenoid, but I have much better piece of mind. I could now reach the solenoid, on the upper right hand corner. I removed the three screws and the solenoid was left hanging by the rusted top hook. I gently wiggled it off of the plastic arm that operates the flapper door. The new solenoid comes with the clip able to move freely and with no rust. Install the new solenoid in the same place and place the top hook onto the arm for the flapper door. Note, I WD40ed the screws and filed some of the rust off of the heads. I suggest ordering screws, like everybody says. But you can clean them up. I did this just in case I need to do this install again. The rest is just a matter of buttoning up everything. It is easy, don´t be intimidated. Anybody can do it, if you are the least bit handy and patient.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: Wolf D from Turnersville, NJ

Ice dispenser flapper stays open

Changed out solenoid and plunger (comes as a kit). Repair was really easy and saved an expensive service call. Note: it is probably a good idea to get screws to go with the solenoid assy (qty 3) plus the screws that hold the dispenser plate to the door (qty 4). Mine were rusty due to the normally moist environment and had rusted, making their extraction more difficult than it had to be.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: A Bit Difficult
Time to do repair: 1- 2 hours
Tools: Screw drivers
Customer: Eugene from Fort Pierce, FL

Ice cube door didn't close

Remove dispenser assembly in freezer door & replace solenoid.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Easy
Time to do repair: 30 - 60 mins
Tools: Screw drivers
Customer: Michael from Fort Myers, FL

Soloinoid did not close valve controling ice cube dispenser and ice accumulated, eventually blocking off shaft ice cubes were dispensed

Removed controls face plate by inserting small screw driver into small holes located below the face plate releasing internal fastening catches and permits you to pull the face plate down and out toward you. Remove the electronic panel now exposed covering the solenoid by removing the 4 screws in the corners. Detach the electrical connector leading from the solenoid ( It may be prudent to unplug the refrigerator as a safety proceedure). Proceed to remove 2 screws holding the solinoid. If the sollinoid is corroded and difficult to remove and disengage from flap(door) controling the ice shaft aperture, it may be necessary to remove the flap by removing 2 small screws holding it in place. Be careful to note the small spring on the left hand side of the shaft which the flap rotates around since it to be re installed in the proper position when the parts are reassembled since it closes the flap after it is opened by the solonoid.
Reconnect the parts and and snap face plate back into place. Good Luck

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: Jerry from hudson, NH

Frost accumulating above ice chute in freezer

Using a small phillips I removed the plastic module containing the ice/water selection buttons by sequentially inserting the screwdriver into 3 holes just underneath the module in the chute opening and pushing up on the tabs while pulling out on the module. Pulling the module away exposes 4 screws that are easily removed allowing you to remove the chute assembly. The solenoid is removed by removing 3 screws and pulling the clip containing the solenoid wires off the electronics board. Reverse the process to replace.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: Blake from Cincinnati, OH

Ice flap would not open

I was this close to calling a repair man when I stumbled upon this site. I would not have been able to attempt this relatively easy repair has I not seen the posts from people with the same problem. It was simple to pop off the cover and replace the selenoid using only about 8 screws total. Thanks to posts by other DIY'rs it was an easy job--this site is Great!

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Easy
Time to do repair: 15 - 30 mins
Tools: Pliers, Screw drivers
Customer: Jer from Mercedes, TX

Icemaker door did not close

Used awl tto release the front panel. Used screw driver to release the solenoid. Ordered a new solenoid. Reverrsed the removal

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: Less than 15 mins
Tools: Screw drivers
Customer: Kenneth from Palestine, TX

Ice dispenser flap would not close causing frosting up of ice tunnel

First I used an ice pick to punch the tabs under the control panel to remove the ice/water selector panel. Then I used a phillips screwdriver to remove the solenoid switch. Unplugged the switch and re-installed with new one I received in 2 days and shazaam it works like new.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 1 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: 15 - 30 mins
Tools: Screw drivers
Customer: Jamie from Bedford, TX

Shoot on freezer wouldn't open to drop ice

First I unplug solenoid from board. I then removed 3 screws holding it in place. I removed bad solenoid (it was very apparent once I took it out). I placed the new solenoid in place, replaced the 3 screws and plug the cord into the circuit board. Success!

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 2 people found this instruction helpful

Parts Used:
Level of Difficulty: A Bit Difficult
Time to do repair: 30 - 60 mins
Tools: Pliers, Screw drivers
Customer: JOSEPH from FORT MYERS, FL

Ice shute flapper did not shut

Used awl inserted into 3 holes at bottom of dispenser toutch pad #93 to release it from mount. Disconnected wire to solenoid & rested panel in door opening. Removed 4 screws holding dispensor housing shield #69. Removed 3 screws holding solenoid & connecting arm #36. Solenoid very rusted. Cleaned inside of ice dispensor with bleach to remove crud & mold. Installed solenoid & reassembled shield & touch pad. Replaced light bulb in dispenser. Flapper now closes tight, problem solved.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

0 of 2 people found this instruction helpful

Parts Used:
  • Dispenser Door Solenoid Assembly
Level of Difficulty: Really Easy
Time to do repair: 30 - 60 mins
Tools: Screw drivers
Customer: Sarah from Marion, KY

Frost build up in the ice chute

We removed the front panel by using a screwdriver underneath the panel to push three little tabs up to unlock the panel. Next we removed the mother board. Removed the old solenoid and put the new one on. It was very easy. We cleaned all he parts that were covered with mildew (yuck) and reassembeled all the parts. Very glad we found this source to do it ourselves. Will order more parts if needed from PartSelect.com

Help other customers find the most helpful instructions.

Were these instructions helpful?   

6 of 20 people found this instruction helpful

Parts Used:
Level of Difficulty: Easy
Time to do repair: 30 - 60 mins
Tools: Nutdriver, Screw drivers
Customer: Timothy from Orland Park, IL

Ice door sticking partially open

removed trim around ice maker and interface display to access solenoid assembly. Found solenoid to be completely rusted out and sticking. replaced the solenoid and works great.

Help other customers find the most helpful instructions.

Were these instructions helpful?   

Model Cross Reference

This part works with the following models:

PartSelect Number: PS1483583
Manufacturer Part Number: WR62X10055
Brand Model Number Description
General ElectricA4425GDTABBRefrigerator
General ElectricA4425GDTAWWRefrigerator
General ElectricA4425GDTBBBRefrigerator
General ElectricA4425GDTBWWRefrigerator
General ElectricBSS25GFPACCRefrigerator
General ElectricBSS25GFPAWWRefrigerator
General ElectricBSS25GFPCCCRefrigerator
General ElectricBSS25GFPCWWRefrigerator
General ElectricBSS25GFPDCCRefrigerator
General ElectricBSS25GFPDWWRefrigerator
General ElectricBSS25GFPECCRefrigerator
General ElectricBSS25GFPEWWRefrigerator
General ElectricBSS25GFPHCCRefrigerator
General ElectricBSS25GFPHWWRefrigerator
General ElectricBSS25JFRFWWRefrigerator
General ElectricBSS25JFRJWWRefrigerator
General ElectricBSS25JFTAWWRefrigerator
General ElectricBSS25JFTBWWRefrigerator - T Series
General ElectricBSS25JFTCWWRefrigerator - T Series
General ElectricBSS25JFTDWWRefrigerator
General ElectricBSS25JFTEWWRefrigerator - T Series
General ElectricBSS25JFTGWWRefrigerator
General ElectricBSS25JFTHWWRefrigerator
General ElectricBSS25JFTIWWRefrigerator
General ElectricBSS25JFTJWWRefrigerator
General ElectricBSS25JFTNWWRefrigerator
General ElectricBSS25JFTPWWRefrigerator
General ElectricBSS25JSRFSSRefrigerator
General ElectricBSS25JSRJSSRefrigerator
General ElectricBSS25JSTASSRefrigerator