Models > ZISW480DMA > Instructions

ZISW480DMA General Electric Refrigerator - Instructions

All Instructions for the ZISW480DMA
91 - 105 of 768
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
burnt out bulb
removed light cover and replaced defective bulb
Parts Used:
Halogen Bulb - 20W - 12V
  • Neal from Gardena, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water in door dispensor quit working
First, I turned off the water supply line to the refrigerator from the house at the wall and unplugged the power cord. Secondly, I removed the small screws that hold the piece of cardboard over the opening in the lower left corner (rear of the refrigerator) by the compressor. Thirdlyl, I removed the other end of the water line where it attaches to the water valve with an adjustable end wrench. Then I removed the small screw that holds the double water outlet valves to the refrigerator frame. I then removed the water valve by pulling it out of the rear of the refrigerator, unplugged the electrical connections, and cut the water lines where they enter the valves. I then plugged the electrical connectors into the new valves and pushed the hoses into their respective openings. These are one-way connectors - once you push them in (firmly) they will not leak or come back out. All I did then was replace the valve and secure it with the one little screw and then replace the cardboard piece onto the rear of the refrigerator. Don't forget to turn the water supply back on. That's it!!
Parts Used:
WATER VALVE WITH GUARD
  • Richard from Temecula, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water dispenser was slowly leaking
Shut off water supply. Unplugged refrigerator. Removed cover. (6 screws -- nutdriver will come in handy). Removed screw securing water valve to frame (again the nutdriver). Unplugged red and white power connectors to solenoids. Using channel locks, loosened nut holding main water supply to valve and removed. Depressed compression fittings to valve and pulled out plastic water lines that supply water dispenser and ice maker. Reconnected main water supply to new part. Pushed both water lines into respective fittings of new part. Reconnected power supply to solenoids. Attached new part to frame with screw. Replaced back cover. Turned water supply back on. Plugged refrig. back in. Problem solved! Savings = $300!
Parts Used:
WATER VALVE WITH GUARD
  • Robert from Huber Heights, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no water to icemaker
turned off water supply, took screws out of bracket, then unhooked water lines. Installed water lines onto new valve, plugged it in then screwed bracket back onto fridge, turned on water and was back operating
Parts Used:
Single Outlet Valve Kit
  • Ron from Clinton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator water dispenser tube (5/16"OD) broken at the back by valve
Tube was too short so I used the union to attach additional tubing to reach the valve at the lower rear of refrigerator
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Peter from Marietta, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak on floor
pulled out refer. found leak at corner lower back, pulled off lower cover. found valve for icemaker leaking. looked in owners/inst guide, pulled up on computer, identified part, called, order overnight part. recieved part & installed, repair complete & successful.
Parts Used:
WATER VALVE WITH GUARD
  • Gerald from Colorado Springs, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set, Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Light switch broke
Your instructions were "spot on"! Pried out broken switch with screwdriver-reinstalled new switch. Very easy! Ordered on line on a Wednesday new part arrived on following Saturday-Great service and will definately use again. Highly recommend PartSelect!
Parts Used:
SWITCH LIGHT FZ
  • Kenneth from Milford, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaky water line to water dispenser
This part (plastic tubing) does not show up under my model of refrig...so I had to look thru the various water lines and pick the one that "looked" right. Luckily, this is the exact replacement part and works perfectly. I removed the lower back panel from the fridge, removed the bracket holding the water line connectors and pressed the outer ring of the coupler up until it released the old water line. I pushed in the new line, made sure it was snug with a gentle pull and ran the line under the fridge up to the existing coupler. I removed the old line from the existing coupler under the front left of the freezer door, and pushed in the new line. I did not need to use the new coupler. If my old line would not have been so brittle and cracked in several places, I could have just cut out the leaking portion and popped the new couple in to mend the line back together. Easy job and we can stop buying bottled water at the store now!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Gerald from San Clemente, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water line was broken at the bottom of the freezer door.
There is no access to the inside of the door to replace the water line. I was able to insert a 1/4" drip line barbed connector into the old line at the base of the door and then connect that to a piece of the plastic tubing which I then connected back to the original water supply tubing with the 5/16" union. It took three attempts to get the tubing through the bottom hinge without a crimp in it. It's best to have a second person to hold the door while you "fish" the tubing through the hinge.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Eugene from Palm Springs, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water for door - leaked on floor
Pulled new tubing to the tank and put a union about 8 inches down from tank to new tubing. Great repair. Parts not readily available locally.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • JOSEPH from SURFSIDE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Parts Used:
WATER VALVE WITH GUARD
  • Jake from Brainerd, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Wrench (Adjustable)
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker barely working
Repair was very simple. Removed refridgerator bottom back panel, about 6 or 7 screws. disconnected bad valve, installed new valve , connected water supply line and then reinstalled panel. Took about 15 minutes from start to finish.
Parts Used:
Single Outlet Valve Kit
  • William from Provencal, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water from the dispenser
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your valve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Parts Used:
WATER VALVE WITH GUARD
  • Anthony from Carmel, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
union connector leaking
replaced with new connector and it worked great. also replaced the water filter and that was super easy!
Parts Used:
Refrigerator Ice and Water Filter Union Connector - 5/16 Inch to 5/16 Inch
  • Amy from Bryan, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Parts Used:
Evaporator Fan Motor
  • Peter from Kalispell, MT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZISW480DMA
91 - 105 of 768