Models > ZISB42DCA > Instructions

ZISB42DCA General Electric Refrigerator - Instructions

All Instructions for the ZISB42DCA
76 - 90 of 513
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Water Leaking from behind refrigerator
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
Parts Used:
Primary Water Inlet Valve
  • Greg from Eden prairie, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
13 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Todd from Saint Paul, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaked
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
Parts Used:
Primary Water Inlet Valve
  • David from Tampa, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water/no ice
The first sign of trouble was when the water dispenser would continue to come out after you let up on the button. Then water and ice stopped. Changed the secondary inlet value and the main water valve, as well as a 1/4" water line running to the freezer (it was cracked). Water is working. Ice maker is working better than ever. New life for an aged refrige.
Parts Used:
Secondary Water Inlet Valve
  • Joseph from Cortlandt Manor, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Parts Used:
Defrost Timer - 120V 60Hz
  • Ben from Warrior, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
knob broke off about 3 years ago, ice/water stopped working about 8 months ago
I only took on this repair on because of the comments I read here...was soooo simple!
Removed the knobs by pulling down firmly, popped off the front panel, removed 4 faceplate screws, popped that off...removed two screws holding the control board faceplate on. Unplugged the old control board, replaced it with the new one, plugged the new one in...replaced all the screws, replaced the knobs and it was done!!! One funny note...be sure to turn the electricity off to your fridge...when you reinstall the board water and/or ice start working right away. I think I'll go have a massage with all the money we saved by not having the repair person come out!
Parts Used:
Dispenser Control Board - 2 Slide Switches Recess Knob - Black
  • Laurie from Hermosa Beach, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Parts Used:
Condenser Fan Motor - 115V
  • donald from opelousas, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost system kept freezing up
took out 4 screws - lowered timer cover - replaced timer- put it back together
Parts Used:
Defrost Timer - 120V 60Hz
  • Robert from Williamstown, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator ice bucket was rusty
My husband just pulled out the defective ice bucket and replaced the new one.
Parts Used:
Auger and Ice Bucket Assembly
  • Eleda from Humble, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water inlet to icemaker freezes up.
Removed the back panel from the lower part of the fridge to expose the valves and motor. Then the one screw holding the valve/bracket assembly was removed to free the assy. It took a few minutes to figure out how to remove the water lines - popped the colored plastic rings out with a screwdriver and removed the lines. Inserted the lines one by one as they were removed to keep correct orientation. Removed the two electrical connections and plugged into new valve. Installed assy with the one screw. Replaced back panel.
Parts Used:
Water Valve and Bracket Assembly
  • Nathan from Portage, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Parts Used:
EVAPORATOR FAN MOTOR KIT
  • Timothy from Orange Park, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not shut off
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Parts Used:
Icemaker Switch
  • Jack from Bloomington, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rubber actuator cover would not shutoff
Replaced the actuator rubber and back plate holder
Parts Used:
Actuator Pad Support Actuator Pad
  • James from Papillion, NE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
11 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coroded Water Valve-no longer dispensing water, then leaked water from bottom of fridge
Ordered the replacement parts-both water valves, printed the schmatic, then removed and replaced both parts. Was fairly straight forward, rmeember to unplg the fridge before you start. Problem solved, should be good for another 10 yrs.
Hard water prob caused the corrosion. Also replaced the water hose while I was back there, water tastes 100% better.
Parts Used:
Secondary Water Inlet Valve
  • Christian from chandler, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the connection on the valve was stripped
After trying to reconnect a flexible hose to the water valve several times I stripped the connection to the water valve, causing it to have a slow leak.

Twice I tried to have an appliance parts store order the part without success. (I even brought them the part from the refrigerator to show them how it looked. ) they ordered the wrong part two times and then said they could not figure out what part I needed.
Finally my wife and I went on line, keyed in the model number and searched for parts of the refrigerator related to the ice maker. We saw the correct part and ordered it ourselves.

It was a success. I changed the part within 30 minutes and the ice maker has been working ever since. I would search and find a part on my own again before trusting someone who supposedly sold parts as their business.
Parts Used:
Primary Water Inlet Valve
  • James from St. Louis, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZISB42DCA
76 - 90 of 513