Models > WRT311SFYW01 > Instructions

WRT311SFYW01 Whirlpool Refrigerator - Instructions

All Instructions for the WRT311SFYW01
31 - 45 of 165
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ref not holding temp
Remove 4 -1-4 screws with nut drivers assembly drops down tstat pups out remove wires replace tstat n put back in reverse !
Parts Used:
Thermostat
  • Robert from LANSDALE, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
Light Socket Kit
  • David from Roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
too much frost in freezer
pulled out gasket and then had to put new gasket in place. Took door off laid it on the kitchen table. Used the small rounded end scissors so that the gasket would get perforated.
Parts Used:
Do-It-Yourself Manual, Ref./Fz Freezer Magnetic Door Gasket - Black
  • Robert from Aston, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
10 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer cold, refrigerator warm
Simply cut wires from old bi metal and joined to new part with wire nuts. Simple repair, but it did not correct the problem.
Parts Used:
BIMETL-DEF
  • Larry from LEWISBURG, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Parts Used:
ROLLER-CAB
  • Hans from OGDEN, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I added an ice maker to a 20 year old refridgerator
I added an icemaker kit. Everything I needed was in the kit. The refrigerator was presetup for an icemaker it was just never added. The only problem I had was that the holes for attaching the water solenoid were not pre drilled so I had to drill them myself and use sheet metal screws. The icemaker is working great.
Parts Used:
ICEMAKER
  • Nicholas from WEST CHESTER, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken tracks on the Meat/Cheese drawer.
The broken tracks popped off with a little effort, and the new tracks snapped in place. No tools required, except a screw driver helped to pop the broken tracks out, and snap the new ones in place.
Parts Used:
Track Track
  • Pamela from PARADISE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor has built in wire harness. The new motor has connectors on it.
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud. Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Parts Used:
Evaporator Fan Motor - 60Hz 120V
  • Leo from EAGLE, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
Light Socket Kit
  • Elyse from Skokie, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the WRT311SFYW01
31 - 45 of 165