Freezer was working fine but refrigerator would not go below 45 degrees
Removed back panel inside freezer replaced fan motor reinstalled panel and was done in about 40 minutes the video on part select explains the repair very accurately
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
The first thing to know on this model is that the handles for the refrigerator and the freezer are identical parts. It is the plastic piece at the end of the handle that breaks. Unfortunately, they only sell the complete handle, which is a shame as it is expensive. To remove the broken Freezer Handle, use a small allen wrench to loosen the bolt on the side. The handle should then slide off easily. You may then remove the two screws at the bottom. Slide the new handle into place, and tighten the screws at the bottom first. This will ensure the handle is properly located. Then tighten the allen bolt on the sidewhile holding the handle agains the face of the freezer.
Refrigerator suddenly not staying cold. Freezer icing up about 1 month before.
Noticed the evaporator fan not spinning but would spin with a finger jump start. After looking up the part on the PartSelect liner parts diagram I found the installation video that really helped. After installing the fan it tested out fantastic. The fan was blowing air 10 times more than the old one. Refrigerator works great on the original econo setting.
First, made sure new fan worked then Placed back in bracket with bushings-only goes in one way, pushed fan back on. screwed bracket to back of freezer and ran the wires to their original place, plugged in the two plugs, put the back piece up attaching ground and pulling ice maker plug thru, screwed back on. Plugged in ice maker, mounted ice maker on freezer wall. Plugged it in. Exact reversal of how it was removed. Not a lot parts to get confused.