Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light would work intermitently
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
Part was easy to order, delivered quickly, installation very easy. Just unplug the unit, pop out the old swich using a screwdriver, disconnect and reconnect leads and pop switch back in. Definitely recommend that you can do it too.
Internal light did not come on each time the door was opened.
After disconnecting the electricity. I followed the instructions as indicated in the "HOW TO" article on the website. I used a steel putty knife and pried the light switch out of its retaining hole. I worked the right side the most since this is the side with the retaining clip. After I removed the switch I transferred the two electrical outlets to the new switch and easily snapped it into place. Engaged the electric power and tested the switch.
My owners manual said to unplug fridge from elec outlet, use a kitchen knife to gently pry off the switch plate (manual had a pictoral example), unclip the two wire, replace with on new switch and replace the switch. Close door and plug back in. Open door to check that the lite works. Walla! It did. Thanks!
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved me $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.
Switch was not working after a repairman had fixed something else
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.
In the morning it was water all over the floor, Fridge stop blowing cool air
Take off the cover of compressor area (lower back of the fridge)Take off the cover of the Compressor Relay and Overload, using flat screw driver; then pull the over load first or you can pull both at the same time; use Pliers and flat screwdriver (ps take a picture for position of the relays and wires colors before), replace old parts with the new ones and put them back, NOTE: before plug it back you may like to check the condenser coil, this is the best time to clean it, if is really bad that can be the reason of relay failure.
Dear Part Select...What a wonderful easy experience....typed in model number...ordered part....it was affordable and arrived in 12 hours....snapped it in...booom.....finished....thaank-you!!!!!
Refrigerator cooling fails to come back on after defrost cycle.
Since the defrost timer turns the cooling functions on and off for each defrost cycle if seemed the most likely problem. That was confirmed by manually advancing the timer with a screw driver and the cooling functions would resume and run until the next defrost cycle (every 8 hours or so). The repair itself was to swap out the timer which took five minutes with a #2 phillips screw driver and a 1/4" nut driver. Once the timer was removed from the cover plate there's a simple plug-in connector to remove from the old and plug into the new timer. Two machine screws hold the timer in place behind the cover plate. Be sure switch the power off on the compressor cabinet before removing the cover plate.