Models > RT18AKXBL01 > Instructions

RT18AKXBL01 Roper Refrigerator - Instructions

All Instructions for the RT18AKXBL01
211 - 212 of 212
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Heard a five second buzzing sound repeated 4 or 5 times per cycle coming from rear lower left compressor side.
Removed the six screws holding the bottom access plate found at the rear of the refrigerator. This gives you easy access to the run capacitor that has a retaining clip. Remove the wire clip and pull out the capacitor (it has two quick disconnect terminals). Reverse the process using the new run capacitor to complete the repair.
Parts Used:
Capacitor
  • Burton from Pecatonica, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
not cooling
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend trying this repair unless you are a pro.
Parts Used:
Condenser Fan Motor Kit
  • larry from indianapolis, IN
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RT18AKXBL01
211 - 212 of 212