Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Parts Used:
Condenser Fan Motor Kit
  • David from New Albany, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Parts Used:
Condenser Fan Motor Kit
  • Nancy from Gallatin, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Parts Used:
Cold Control Thermostat
  • Henry from Newland, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!