Models > LAT7500ABX > Instructions

LAT7500ABX Maytag Washer - Instructions

All Instructions for the LAT7500ABX
61 - 75 of 154
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Small puddle of water after the washer went through a complete cycle
I removed the two screws that held the front panel in place. Then I removed the two screws that held the top down. This allowed me to see the siphon valve when I lifted the top up. I disconnected the hose from the pump to the siphon valve by taking off the 2 clamps. Then I went to the back of the washer and moved the drain hose from the back by looseneing the clamp. Then I unscrewed the 4 screws holding the siphon valve in from the back. I took off the old valve put the new valve in and reversed the process to reinstall. It fixed the problem.
Parts Used:
Siphon Break Connector Kit
  • Daniel from Oviedo, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Washer tub overflowed with water after turned off and machine not used for several days.
Simple removal of the mounting plate holding the old valve to the rear of the machine followed by disconnection of the water hose to the washer from the valve and unplugging of four electrical connections. Reattached the new valve to the water hose and then reattached the new valve to the mounting plate, finally reconnecting the wiring connections (4). Installation completed by reattaching the valve mounting plate to the washer. The diagnosis was confirmed by blowing into the old valve's water inlet. Air would pass through the valve, confirming that it did leak when the valve was closed. Air blown through the new valve prior to installation would not pass through the new valve.
Parts Used:
Water Inlet Valve
  • Robert from Amenia, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Hot water would not full shutoff during cycles, causing over flow
When the part came in, it was just a matter of getting the old part out, and replacing it! Incredibly smooth---the hold down screws were obvious, so once I got them out---the part came out of the machine, I disconnected the two control wires, reconnected them to the new part---and reinstalled!
Parts Used:
Water Inlet Valve
  • ALISA from Kathleen, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Low cold water flow during fill
Part shipping was great got here in two days-

I pulled off Front panel (two screws) and lifted Top panel (2 screws) and disconnected the inlet hoses. I removed the old Inlet valve. (1 scew and valve to tub hose connection).

Before Installing the new valve, i shifted the connector positions on the selenoids to match the old valve. and installed by reversing the steps. All went very smooth. Thanks, It was easy.
Parts Used:
Water Inlet Valve
  • Jeff from Diamond Bar, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water inlet valve had a crack and was leaking water.
I first shut off the cold and hot water hoses so that no water would run while replacing the part. After that I made sure to unplug the washer .Then I removed the plate that was holding the water inlet valve with a 1/2 " nut driver ,I think there were four bolts .Then I removed two more bolts from the center of the plate that were holding the water inlet valve.I then disconnected one 1/4 " screw or I should say loosened one which held the main water hose going into the washer which then released the part ,except from four wires. I then took one wire off at a time and attached to the new part one at a time.Finally, I was finished and reconnected everything .It worked perfected !I'am very happy and pleased . This washer is over 25 years old and still runs .
Parts Used:
Water Inlet Valve
  • Eric from Brook Park, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water would not enter washer.
Change the position of electrical connection on inlet valve before installation to match positions of old valve. Shut off electricy and water to washer. Disconnected water hoses, and power wires to old valve. Removed old valve and installed new valve exactly as installed on old valve. Washer operated perfectively
Parts Used:
Water Inlet Valve
  • Tevis from Albemarle, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Wrench set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
After first spin, cold water comes in for rinsh, the water would not come in, but would run out on floor.
Removed old valve and replaced with new. Wire for wire..screw for screw..
Parts Used:
Water Inlet Valve
  • Cas from Cary, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Washer was leaking from the siphon break. A little difficult to find, as the water would ru down the drain tube & make you think that the leak was elsewhere.
I removed 2 screws at the bottom front corner of the washer. Then lifted the front panel upwards about 45 degrees, which allows the front panel to be removed.
I then removed one small lag bolt from under each front corner (with a nut driver), which hold the top to the frame.
I was now able to swing the top up to have access to the siphon break.
I then removed the drain hose from the rear of the machine where it is attached to the nipple end of the siphon break, by loosening the hose clamp. Still at the rear, the nipple end of the siphon break is attached with 4 mini lag bolts, Which go through the back plate & hold the siphon break to the inside of the washer. I removed the bolts with a nut driver.
The nipple end now fell away. You must save it, as the siphon break does not come with a new nipple end.from the siphon break. Maytag attaches it with an iron band, as they must think that this repair will never be done! I cut the band with the Dremel, being very careful not to cut the hose.
I pulled the siphon break free from the hose.
The installation is a reversal of the removal, starting with inserting the siphon break in the inner hose, clamping the hose with the supplied hose clamp.
I the removed the inner drain hose
Parts Used:
Siphon Break Connector Kit
  • Bengt from Matawan, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Washing machine was filling very slowly
I checked the inlet hoses for hard water build up and noted that this was not a problem. Then checked the hose from the inlet valve to the washer drum and determined that it was clear so I knew the problem was a faulty inlet valve. After receiving my replacement valve, I removed the old valve by removing the hot and cold water hoses and unscrewing two screws securing the inlet valve and lifting the inlet valve out the metal holding bracket. This gave me complete access to the inlet valve allowing me to remove the hose clamp and hose to the washing machine drum. The new inlet valve was an exact match so I removed the four electrical wires one by one while putting them back on the new inlet valve to insure correct electrical connections. I added a piece of one half inch plastic tubing provided with the new inlet valve on the outlet nipple of the new inlet valve to prevent leaking. I then put the new inlet valve back into the holding bracket and screwed it down. I replaced the hot and cold hoses to the new inlet valve carefully so as not to cross thread the plastic connection on the new inlet valve. After turning the water back on, I checked for leaks and plugged the washing machine back on to test it with a washing cycle.
Parts Used:
Water Inlet Valve
  • Paul from San Antonio, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers, Socket set
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water would not shut off, even after removing power.
Exactly as the video showed. This was a very simple repair. The only extra thing I did was to replace the mesh screen/gasket at the hose ends. They were plugged with crud. PartSelect saved me from buying a new washing machine. Yay!
Parts Used:
Water Inlet Valve
  • David from Belchertown, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water coming in the wash tub when not in use
I took the hot and cold water hoses off with pliers.and then I took the one screw out towards the top of the water inlet valve plate.disconnected 4 wires,there is a small clamp on the small hose on the valve you have to remove.and last there is a cluster of wires that has to be removed from a bracket and (it is important to put these cluster of wires back in place otherwise they will wear a bare spot in them.)
Parts Used:
Water Inlet Valve
  • JEFF from FORT HILL, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Slow fill using hot water
My experience with my repair is as follows:
After determining the "hot water" solenoid was weak and that a new fill valve was needed, I placed my order with PartSelect on Thursday and to my suprise, had it in my hand Friday evening (no special shipping). WOW talk about fast! But unfortunately the part was broken.
Called PartSelect back Saturday morn to explain my problem and was told that I would be credited for the broken part and that a replacement would be sent ASAP probably arriving on Wednesday. Again to my suprise, the part arrived on Tuesday morning.
Hats off to you guys for great service, prices and no hassles.

Dennis Fleming
North Billerica, MA
Parts Used:
Water Inlet Valve
  • Dennis from North Billerica, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water stopped flowing
pulled the front panel first, then lifted the top(2bolts in each).
Then unhooked water and unbolted the water inlet valve from the back left corner behind the tub.four wires are connected Pay attenion to where they go, for easy reinstallation.NOTE: watch the clips in the front of the washer they flew off and it took half an hour on the internet finding out how they went back on.
Parts Used:
Water Inlet Valve
  • michael from Pearland, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water would not shut-off at initial filling of tub, hence washing cycle would not start. (This condition could have gone on for days as the water exited the wash machine as fast as it entered.)
Removed the front of the washing machine. Located & removed the water inlet valve from it's mounting on the back
inside face of machine. Replaced water valve, & restarted machine. Like new again!

Can't say enough about the speed of parts delivery & professionalism and accuracy recieved from the team at Parts Select. Thanx again,

Greg W.
Parts Used:
Water Inlet Valve
  • Greg from Bethel Park, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water continued to trikle in machine
took hose off then took three 5/16 screws then clamp off reversed order to put back on check for leaks ok
Parts Used:
Water Inlet Valve
  • John from Colmesneil, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the LAT7500ABX