Loose terminal caused block to overheat and break
Removed all terminals and block mounting screws. Repaired one burnt terminal and reassembled. Replacement part was an exact fit and reassembly whnet very well.
cut power off and placed sturdy table same height as bottom of oven in front of oven. removed trim screws. pulled oven out onto table. removed top cover and panel on left side . tested transformer to be sure it was bad. then replaced transforner
The replacement turntable we received was an exact duplicate of the original. It was as easy as rinsing the new turntable, taking the old turntable out and putting the new one in.
Used the instructions I wrote up the last time. Printed them off, and still works like a charm.
This makes third time the spring has broken - last two times it has been the right side spring. Not the best designed microwave door. But at least with PartSelect having the part, and with PartSelect keeping my original instructions on the website, the repair is easy.
I followed the instructions that were posted for a do-it-yourself on the part. The instructions were spot on. One addition that I have to the online instructions is that I have a wall mounted microwave and had to remove the trim before starting the instructions. Additional instructions for wall mount are:
1. Remove one screw each side from inside the door to loosen the vertical trim.
2. Remove the vertical trim on each side.
3. Remove the 2 screws holding the bottom trim and remove the trim.
The left most crew of two holding door front was not accessable due to closeness of lower oven vent.
Found a way to remove screw. Proceeded to insert new spring and tried to assemble but had same problem to put screw back in. No normal tool was able to fit in and could not remove vent. Finally able to engage screw and finished reassembly.
Removed door to see what happened to the spring, ordered new spring and door frame on line and replaced parts. Had to replace door frame as it broke while removing it.