Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Looking at the ice maker it is pretty cut & dried as to how to remove the unit. I took out the ice tray and just started removing all the mounting screws. The same for the mold ice tray & heating element. I was just sad that you did not have just the heating element separate from the mold ice tray.
The ice mold has a coating on it. Over time the coating deteriorates. If your ice maker leaks water into the ice reservoir inspect the mold to see if the coating is compromised. If so, replace with new.
Remove the ice maker assembly. 3 small hex screws. Unplug power cord. Disassemble ice maker assembly. Remove ice mold/heater. Replace with new. Reassemble.
After lots of internet exploring and diagnosis, the icemaker comes right out, and with three screws out and in, the job is all but done. Don't pay anyone for this repair!!!!!
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
I removed the cap from the filter pushed a lever and removed fliter. I replaced the old filter, removed the caps on the new one and slid it into channel after replacing the outer cap. I removed water from the spigot for 4 mins. and it was ready to go. I pushed the reset button to get the green light to come on.
The lining of the ice mold (Whirlpool) started flecking off (black flecks in the ice cubes), so I decided to replace the mold. Loosen the two 1/4 inch upper nuts and remove the lower nut to remove the ice maker from the freezer. The hardest part was getting it unplugged. I used a small blade screwdriver to release the catch on the connector and pull it out. Remove the ice maker front cover. If you have a skinny enough phillips screw driver, there are two deep set screws through two holes on the lower portion of the control module (otherwise, remove the three screws on the controller, unlatch the shut-off arm from the control module, and separate the controller to access the mold screws). Unhook the shut-off wire from the end of the tray. Unscrew the two screws holding the mold and remove the mold. Remove the plastic hardware from the old mold and install on the new mold. Attach the new mold on to the control module. WARNING WARNING WARNING!!! The mold I bought already had the alumilastic on it for the contact point to the thermostat. When I installed it and tightened the screws, the alumilastic was dried out, didn't squash down, and dented the bi-metal thermostat on the controller, ruining it. I had to buy a new thermostat. Be sure to check that the alumilastic is pliable. If not, take it off and buy some fresh to put on there. Re-install the ice maker. It took a while to get the first batch of ice because the ice maker was at room temperature and I had the freezer door open for several minutes. So the freezer had to get cold and the ice maker had to chill down. Once everything got cold, it started making ice again.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Unlug refrig or turn off refrig from its control panel On/OFF switch. For ease of work remove freezer shelve directly below the ice maker. Remove four screws from the bottom of the ice maker assembly, three that secure the ice maker and the other that holds a plastice shroud in place over the ice maker's power plug. The ice maker is now ready to be removed; it will slide forward by pushing up on left and right side of the ice maker's mounting slide rails. Once the ice maker is moved forward it is easier to disconnect its power plug (depress a locking tab on the side of the connector and pull connector apart and remove ice maker assembly. Remove and replace motor module by removing three screws and and replace with new unit. Reverse ice maker removal proceure for installation. Once installation is completed turn on Power to Refrig, Ice making should begin after a few hours.
The troubleshooting time takes about 20 to 30 minutes. After checking out the solenoid (valve water), the water line, and the electronic board (emitter/receiver) are working fine. The only thing left is the ice module. I called Partselect and talked to a sale rep to make sure I get the right part, and the lady was so helpful by sendind the picture of the part so I can review before ordering it. I received the part in 3 days ( normal shipping) and did the folowings: 1) Unplugged the power cord from refrigerator. 2) Removed the ice module by removed a 1/4" screw from under the right side of the icemaker that retains the icemaker and a “U” plastic clamp and then pull out the whole unit it from the track. 3) Unplugged the cable connected to the ice maker. 4) Using the phillips screw driver to remove the 3 screws. Carefully pulled out the ice module and installed the new ice module. 5) Put the ice maker back to the freezer, plug the cable back to the ice maker and put the clamp and tighten the nut. 6) Plugged the power cable back to the wall.
The first ice I got in an hour and a full bucket of ice in less than 24 hours. I spent less than $80 for the whole thing. Thank you so much Partselect for the great service and the stories posted, it really helped me to get it done.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced. reassembled the pieces.
Local service person missed the diagnosis and advised $10,000 new refrigerator. I looked and saw that the switch was deformed and had burn marks. Searched for switch online. Found site Ordered. Part arrived next day. 5 minute job to replace. No tools needed. Refrigerator works great. Thank you t!