Refridgerator/Freezer Not Cooling
First of all, let me say that I'm a 50 year old single woman. If I can do this repair, anyone can! After unscrewing the back of the unit that houses the compressor, I found the relay overload switch which is attached to the compressor. I pulled the part off and discovered that it comes in one piece. The replacement part came in 3 pieces. I intially thought they sent the wrong part. After a little thinking outside of the box, I figured out that the replacement part was indeed the correct part and that it comes in 3 pieces instead of one. It would have taken 5 minutes to repair if I had realized this early on. Once replaced, the refrigerator/freezer was cooling within 10 min. I sent the Run Capacitor back after telephoning a customer service rep. She was so courteous and helpful! What a fabulous company. I highly recommend. I saved myself approx. $250.00 doing it myself.
Parts Used:
Run Capacitor Relay Overload Kit
  • Melinda from Modesto, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
44 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not exit defrost mode (continual defrost)
Unplug the refrigerator. Remove face plate located in the upper back of the refrigerator compartment. Remove face place bracket on the right using nut driver. Removing these screws also frees the metal case enclosing the Defrost Timer. Pull the case away from the back of the refrigerator exposing the Defrost timer. Remove the electrical plug from the Defrost Timer. Then remove the Defrost Timer from the case by removing the two screws securing it. Reverse the procedure to install the new Defrost Timer.
Parts Used:
Defrost Timer - 120V 60Hz
  • Leon from Chaparral, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
44 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster element and or thermostat was not working.
removed the shelves in the freezer compartment and removed the two screws holding the back panel on over the coils and simply removed the male wire plug from the female plug and pulled the wires for the heating element down thru the coils and released the spring clip holding the element in place and removed, and installed the new element and thermostat in reverse order. Very simple.
Parts Used:
Defrost Heater and Thermostat Assembly
  • Thomas from Cottage Grove, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
39 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Yoke auger tore hole in plastic ice enclosure
Very simple repair. First Remove ice tray. Next remove enclosure. Believe there were 3 screws to remove enclosure (1 bottom, 2 top). Slide enclosure out slowly to gain access to power connector mounted on back wall. removed components from enclosure (motor and solenoid). Take extra care removing solenoid with spring/rod as it is 3 separate pieces (spring, rod, and coil). Easy to figure out reassemble but easier if you take note during disassembly. Took me a while to get yoke off from motor assmbly. noticed they were reverse threads (lefty). So to remove yoke from shaft had to turn CW vs CCW on regular threads. Once had yoke off, rest of assembly was easy. Mounted motor, reinstalled yoke. Put entire re-assembled enclosure back in fridge. Slide in part way, to give yourself plenty of room to plug power connector in. Reattach assembly with 3 screws. Works like a champ.
Parts Used:
Ice Enclosure
  • Craig from East Fairfield, VT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
36 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor "grounded" and quit running
Replaced the compressor with the new one I purchased from you. Installed new parts and recharged unit. The refrigerator / freezer is working better than new. Thanks for the great deal on the compressor. It was here in 3 days. All the parts fit exactly and had no difficulty in the installation or startup. The directions for the wiring were a great help also. Thanks again.
Parts Used:
Compressor Kit
  • Mike from Baytown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
59 of 118 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refigerator not cooling
Through experience I determined the problem was with the compressor trip switch. It's the small white piece that looks like a flat fuse.

The parts arrived in 3 working days. Instructions were included - very easy to understand. From start to finish I replaced the switch in about 15 minutes. Frig is now working perfectly.

3 pieces come along in the kit - however, all I needed was the switch, but for the price I changed out all three to assure compatibilty.

I also ordered the cover which was not needed.

A Happy Customer! {:-)
Parts Used:
Relay Overload Kit CLIP
  • Ronald from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench (Adjustable)
35 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
Parts Used:
Water Tube Connector/Union - 5/16 to 5/16
  • Leo from Salem, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
43 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Water Fill Cup and Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
doesn't get cold at all and freezer was warm condenser wouldn't run
removed all 6 screws in back of fridge. located the condenser the relay was a white like circut to the left of the unit. The entire pience comes off easy using a flat screw driver to pry it off the pins.
The replacement came in 2 pieces insted of 1.
I replaced the relay and then the overload reconnected the wire harness back the way it was before. The new relay has a larger connector prong for the live wire so the kit comes with a jumper wire so the original wire harness can be used without splitting the cabel made the repair very easy. Also the new capacitor is bigger and better so I replaced that as well. The capacitor makes sure the relay gets stable current so its good to have a working one.
Parts Used:
Run Capacitor Relay and Overload Kit
  • Jean from Fremont, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
27 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Parts Used:
Replacement Ice Maker
  • Shelley from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice and Water Dispenser Would Run on After the Glass Was Removed
I am going to be completely honest here. This problem had persisted for months. I finally decided that I would buy all the associated parts and repair the unit hoping to cover the problem. Much to my surprise, after carrying out the repair, using the instructions provided by PartSelect, I still had the problem. I decided to remove and LUBRICATE the button which depresses the Limit Switch when you push a glass against the rubber membrane. Low and behold the problem was solved. The frig is nine years old, so I feel I may have prevented other problems in the future by replacing the three parts. It was a follow the directions sort of repair. I was very pleased with PartSelect response to my order (received it next day) with standard shipping.
Parts Used:
Limit Switch - 2 Terminal Dispenser Control Board Ice Dispenser Solenoid and Door Kit
  • Doug from Berkeley Springs, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Hollow Ice Cubes, Stuck Icemaker & no more cubes
We have a Reverse Osmosis water filter supplying the fridge, so the internal water filter only served to reduce the water pressure inside the unit. I installed the bypass plug by simply twisting and removing the internal water filter and then twisting the plug up into the same hole. Done in 5 min.
Longest part of this was clearing the top shelf to reach back there... Oh, and figuring out that this part exists and that it could help with the problems we were having with the unit. The water filter is relatively new, less than six months, but it still contributed to the problem enough to cause the failure.
[Thank you Partselect.com for having this web database set up that gets EXACTLY the right part!].

Now about the hollow cubes: Do a web search and you'll find a lot of discussion about it. This is specific to the Whirlpool (Maytag, and others) newer style front to back icemakers that create "half moon" shaped icecubes. For a Shop Manual to a web search for 4316835.pdf for this series.
No doubt my old unit's icemaker solenoid valve on the back isn't passing as much pressure as it did new, but by itself it isn't fatal just yet. You can tell if you are vulnerable to this if the water spigot on the front only delivers a very slow trickle of water; if it takes a l o n g t i m e to fill a glass.

But here is the rest of the story: There is a fundamental design flaw in the way the icemaker unit was created that makes it malfuntion if the water pressure is too low - they chose to put the thermocouple (TC) that senses the temperature of the freezing cube on the opposite end (front) of the water tray from the water fill tube which fills from the rear. This was probably a manufacturing trade off for simplicity of assembly and it saved them half a cent's worth of copper wiring and a couple of screws. And maybe a safty concern about wiring under an open water channel, but that is a lousy excuse; there are other solutions, and the power "harness" goes right by there within a couple of inches anyway...

There are a number of reasons for low pressure:
- Bad supply inlet valve, or not open all the way, crimped tubing
- Bad Frige icemaker solenoid valve
- Clogged internal water filter (even just a little)
- Frozen ice plug in the fill tube, in the very back top of the unit against the back (use a hair dryer to defrost)
- Etc. Do some more web research for more details.
Of course the icemaker timers do fail as well, so this discussion assumes the icemaker is still functioning as "normally" as it can, given its design limitations.

The interaction with water pressure (design flaw!) is this: if the unit doesn't get enough water due to low pressure, then the final cube position to fill doesn't get any water in it (the front one by the motor). This is the one that the TC is next to as well, so it cools of really quickly and the TC thinks the tray is completely frozen, when in fact it isn't. The TC fires the cycling motor which turns on the heater and then spins the ejector shaft which has tabs that push the half moon shaped cubes around and out. However, since the cubes weren't fully frozen, only their outer shell gets pushed out - the water in the middle drains out leaving a hollow cube set. That liquid water hits the cold ejector bars and some of it immediately freezes, making little stalactite fingers that catch on the tabs and side of the tray, thus jamming the ejector shaft and pausing the cycle in place indefinitely.
The net is that you get a few hollow cubes and then no more ice until you reach in and crack off the ice fingers so shaft tabs can pass and the motor can finsh the cycle and properly stop in its home position. You can also tell by checking whether the front cube location has water in it just after it fills by reaching around and dipping your finger in it. If it comes up dry, then you have this problem.
So, in my case, putting the bypass plug in increased my flow t
Parts Used:
Water Filter Bypass Plug
  • Jonathan from Scottsdale, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
23 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I pulled the fridge out to vacuum the coils and noticed the fan was not working
First I removed the cardboard cover, which was held in place by 7 screws. Actually first I unplugged the fridge, next using a nut driver I removed the 3 screws holding the supports to the motor. The motor with fan just pulls right out. Next was to disconnect the wire harness or plug, which required squeezing together the plastic plug and moving it side to side while gently pulling.
With motor in hand using a pair of pliers remove the poor excuse for a nut of the fan motor shaft holding on the fan. Slide the fan off the shaft -note direction of blades!!!! Using a nut driver remove 2 srews holding on the plastic motor support . This slides right off the back. To assemble follow the reverse . Just check to see that the fan spins freely before plugging back in your fridge.
Parts Used:
Condenser Fan Motor
  • Gray from Gilead, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
21 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Parts Used:
Replacement Ice Maker
  • Kevin from Tyler, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Door Would Not Open
Jenn-air jcd-2389gtw refridgerator/freezer side by side ice door would not open to dispense ice from the ice dispensor I did an online order for the repair kit #ps2003478 (115v) ice dispenser solenoid and door kit to fix the problem with the ice door not opening. As I had deduced, the “solenoid” had gone bad, and the kit held most all the items required to make the repair. The only additional item the kit needs to have is the “fountain door return spring”. Be careful not to loose the spring when disassembling the unit. You might want to order an additional spring just in case you loose or break the original. The instruction sheet was pretty thorough, except for being small and the pictures hard to see. My refrigerator/freezer has decorative panels that had to be removed before I was actually able to get the escutcheon off of the unit, and this configuration wasn’t addressed in the instructions. After figuring out that I had to remove all the trim from the door of the freezer before I could start the repair, the job wasn’t that difficult, but you have to have patience and take your time to make sure you don’t damage the electrical components of the ice dispenser. Make sure you note the position and location of the fountain door return spring before you remove the ice door!! This is important so that you can get the correct “tension” when reinstalling the mechanism. If there isn’t enough tension on the spring, the door will not seal properly, and the dispenser will freeze up. Also, when it comes time to disconnect the “electrical edge connector” from the control panel, be sure to make note of it’s position. It isn’t difficult to pull off, but could be easily broken if you are not careful. The rest of the repair and installation is straight forward and simple. Just take your time and it goes back together pretty easily. Tools you will need are; needle nose pliers, phillips screwdriver with a small and medium bit, and a “torx” tool set to remove the torx screws from the escutcheon and fountain bracket.
Parts Used:
Ice Dispenser Solenoid and Door Kit
  • Stanley from Southlake, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JSD2488GEQ