Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Removed outer case, checked fuse first, it was good so went to thermostat. No continuity reading. Unhooked thermostat, used jumper wires to by-pass break—briefly plugged the unit in. It came on so I knew the issue was definitely the thermostat.
Open door. Remove tray. Remove old roller assembly. Insert new roller assembly. Replace tray. Close door. It took more time and effort to unpack it than it did to replace it.
completly removed outer cabinet,discharged capicator,removed some internal parts so I could get at the magnetron, .removed replaced magnetron,reinstalled inner parts& cabinet .tested microwave viola everything worked again. Thanks, PartsSelect Ernie
Removed the outer cover to access the door switches. Turns out there were three switches, but I determined that only two were bad. When the small colored tab on the switch is pushed in it should make a clicking sound. The two bad switches had no resistance and did not make any noise when pressed. Removing the switch is relatively easy, you simply pull it away from a couple small tabs holding them in place. After reconnecting the wire leads, insert back into the holding tabs and install the cover.
The microwave turntable rotates when the door is open.
This is sometimes described in other repair notes as "microwave 'runs' when door is open." With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open. Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower. There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon. Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
Pulled it from the wall remove the front vent covers removed the control panel remove the door switches by a special screw driver bit which looks a star remove the electrical terminals pressed the plastic clip pulled the switch replaced it with new one then followed initial steps backward
I took the cabinet off and saw where the switch had been burnt. So I remove it and order another one from your company. And I put new clips on it with heat shrinks. We might get another 30 years out it, Although I'm 80 years old.
time would count down but unit would not run & heat.
remove cover, unplug secondary door switch (top switch) remove switch from holder, install new switch, plug in wires, replace cover, very easy. door switches are a common problem with microwave ovens.