Models > JE740W > Instructions

JE740W General Electric Microwave - Instructions

All Instructions for the JE740W
31 - 45 of 119
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
PS240270 Ceramic Fuse - 15 Amp
PS240270
Ceramic Fuse - 15 Amp
Easy installation , remove microwave cover housing ,locate fuse by door catch & replace..
Received quickly..
Replaced fuse , removed microwave cover housing , located fuse adjacent door catch removed & installed new fuse...
Parts Used:
Ceramic Fuse - 15 Amp
  • Rob from NEWTON, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turn table won't turn.
Turntable in the microwave stopped turning.
Parts Used:
Synchronous Motor
  • Gerald from Fort Eustis, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
12 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave wouldn't start after "Start" pushed
Took cover off, noted the two side by side switches easily visible and we hought one of these was responsible. Then son noted a third switch at the top of the plastic assembly which inserts at an odd angle. When it was inspected signs of a previous short showed up with burnt contact points. Reinserted at same odd angle as there were guide holes, closed things up and oven worked 100%. Great prompt service and great website!! We will use you again
Parts Used:
Secondary Door Switch
  • Don from Monte Sereno, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven blows 20 amp fuse
Primary door switch was shorted and blew the fuse when the oven was plugged in. Replaced primary door interlock switch.
Parts Used:
Secondary Door Switch
  • PATRICK from Covington, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When you open the door at the start the fan wood come on
I removed the unit from the wall removed the top two screws holding the panel above the door I the two screws holding the control panel removed the three switchs I found the top one to be blown and replaced it
Parts Used:
Monitor Door Switch
  • Larry from CHARLOTTE, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave would not start
took of cover removed switch and replaced with new one
Parts Used:
Secondary Door Switch
  • JULIA from JACKSONVILLE, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ove black out
must of had loose connection from wire terminal
to thermostat from factory. thermostat and wires
were melted. removed thermostat. and cut burnt
wires back. replaced thermostat and terminals.
used better quality terminals than factory.
also checked and tightened other loose connections. there was enough wire left after cut back to just put on new terminals.
Parts Used:
Thermostat
  • Glen from Highland, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No cooking Power
Had to remove outer cover (special screws involved). Found the correct part at PartSelect.Com and it arrived 3 days later as promissed.

This oven has diffcult electrical connections at switch to get disconnected. I found it easier with the sw loose and in hand so that the connectors can be released with a small screwdriver.

One has to this in order to test the part wirh an ohm meter. I found the sw did not close but remained open and thus caused the oven not to function.

Removing interconnect switch is tricky but not difficult.

Outer cover replacement is not as easy as it should be, especially the sides.

All is well and working.

Microwaves are simple devices if you are know how to read and understand schemetic diagrams.
Parts Used:
Primary Door Interlock Switch
  • Norbert from Minnetonka, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When running a burning plastic smell coming from the venting air.
Took the cover off (removed the five screws, two of which were security screws off the back) and found one connector on the thermal cut out with its shielding melted. Very easy swap out of the new cut out and we were up and running as if new.
Parts Used:
Oven Cavity Thermal Cut Out
  • Paul from Modesto, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave stays on when door opened
Removed control panel first then removed bracket holding door switches 8 screws total very easy fix ????
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Charles from OAKDALE, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave powered up when door was opened
After researching on line and watching installation videos, ordered all three switches and installed. Disassembly of microwave was simple, removing the bracket holding the switches was a little tricky, it sits behind a metal post and you have to angle and wiggle it out. One note of caution when replacing all three switches, be sure to install correct switch in correct location. Had two of one style switch and one of a second style, and put one in wrong place, causing microwave to power up again when door was opened. After thinking it through and doing a second disassembly, and double checking installation instructions, corrected problem and microwave now works fine.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Ken from WARE, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave did not operate
this is not fair to the do it yourself person because I have been an electrican for forty one years I removed the cover spotted the burnt limit switch ordered the part replaced the part and checked operation of the microwave thanks for the painless task of locating and ordering of needed part
Parts Used:
Oven Cavity Thermal Cut Out
  • Kenneth from Giddings, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave dead
First, potatoe burned up in microwave. Microwave
was dead. Took off cover and found maintaince repair pamphlet in envelope. Schematic showed one shot thermostat for fire. Ordered thermostat from you and installed it. Works fine.
Parts Used:
Thermostat Cut-Out
  • Jerry from Lillian, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave would not heat
First remove all screws holding on outer metal casing of microwave. Next remove the back and bottom metal pieces. You will then be able to pull aside the outer casing so you can access the door switches. Check each switch with an ohm meter in both the open position and with the switch closed. If the ohm meter reads the same in both the open and closed position, the switch is bad. Check the top switch first. Replace switch and reassemble. Cheap fix for a costly microwave. Great customer service at Parts Select!
Parts Used:
Primary Door Interlock Switch
  • John from Erie, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Oven overheated
I thought I was setting the timer only on the microwave and accidently cooked an empty oven for 10 minutes. It was dead and I used the schematic and figured out the problem. Got the part and installed in 10 or less minutes. Oven is back in action.
Parts Used:
Oven Cavity Thermal Cut Out
  • David from Collegeville, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JE740W