Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Door Seal was falling apart
Replacing the door seal only involved unscrewing about 50 screws, attaching the new seal, & screwing all 50 screws back in. I'm glad I have a good electric screwdriver. The hard, if not impossible part, is trying to get the door to seal properly again. At first the door wouldn't close all the way, so after 2 hours of tinkering, it will close now, but the top left corner of the magnetic gasket will not seal no matter what.
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Removed the one and only screw inserted vertically up to hold the control console to the top of the fresh food compartment. Disconnected the electrical connectors ( two ) and laid console on work bench. Studied the temperature control installation first, then removed wire connections. Installed the new control same as old one, and reinstalled the console in the fresh food compartment of the refrigerator. Service from Part Select was excellent ! Great diagrams, pictures, etc. Great help to locating part ! Ordered part, and bam, here it was in few days ! Great customer support ! Five stars !
removed card board protection.4 screws. Unpluged refrigerator unscrewed the screw holding the valve but not all the way. disconnected the electric connection. removed the water connection after disconnecting the main water valve. replaced valve by reconnecting everything. Turned on water to check for leaks. Easy fix and recieved the part sooner then expected. Will highly recomend your fast service and correct part replacement. web site was easy to use. THANK YOU
First I unplugged the refrigerator, then next I removed the (4) screws holding in the inside back panel section of the freezer covering the cooling coils, the fan motor is attached to the removable panel. I then unplugged the wiring harness to the fan motor which allows you to completely remove the freezer inside panel in order to replace the fan motor on a counter top or benchtop. I removed the (3) spade terminal wiring from the fan motor and the nuts holding the motor on the frame. I then replaced the fan motor and blade the same way I had removed the old one, and then reattached the wiring terminals on the same terminals as the existing motor, making sure that black, red, and green do not get mixed up. I placed the rear panel back inside freezer and plugged in the wiring harness, fit panel back to original position and reinstalled the (4) panel screws. I once again plugged in the refrigerator and restored power. Everything is working fine.
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
I removed all contents from the lower shelf. I, then removed both of the pull out drawers. Secondly, I removed the lower glass shelf and the glass support tray. At this point all four plastic shelf supports were accessible. I removed the inner screw from all four supports and replaced with four new shelf supports. Then reassembled in reverse order. Very easy to do!
noisy fan motor, fridge & freezer not holding temp
I took off the ice maker, disconected the wiring, took out the back of the freezer and took out the fan motor. Harder than I thought because of all the wiring back there, light, fan assembly etc. After that it was easy, took out the old motor & installed the new one. Runs much quieter now, and the fridge & freezer are much colder. I did this for less than the price of a service call by a repair shop.
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
The repair goes much easier if the door is removed. The door is bulky and that's the difficult part. Once its on the table, unscrew to get old one off, put new one in place and re screw. (there are many screws) Then bulky door needs to be placed back onto the refrigerator. Again difficult positioning, weight, bulky. The door comes off and goes on very easily (2 mins to get off, 10 to put back on). Just 3 lower screws. This job could have taken less than an hour if I had started with a removed door.