Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
Parts Used:
Defrost Timer - 60Hz 120V
  • Doug from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Parts Used:
Run Capacitor
  • Frederic from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My ice maker quit making ice.
I removed an access panel loosened the two screws that was mounting the water valve to the refer frame. I took off the three lines to the valve and unplugged the wires from it and reinstalled the new valve. The whole job took 5 minutes.
Parts Used:
Dual Water Inlet Valve
  • Randy from Great Falls, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The plastic that held the drawer in place broke
I called Part Select and ordered a new drawer. They got the item to me within 3 days! I would definitely recommend them to a friend.
Parts Used:
Lower Crisper Drawer Lower Storage Drawer Front
  • Ann from Marriottsville, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
wonnt defrost
removed back cover from freezer to replace defrost stat. removed cover from refrigerator to replace defrost timer
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • bruce from grand haven, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leak in the water tube elbow
First I remove protection cover,then removed the elbow pressing in on the gray coupling housing at each end of the elbow.Mark each piece of water hose before removing the elbow with marker(black)it helps when replacing new elbow.The new elbow slides on each end of water hose ,connect the end to the hose coming out of the door first. Replace protection cover. No more leak.
Parts Used:
Water Tube Elbow
  • Vaughn from Virginia Beach, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer coil was frosting up blocking airflow to refrigerator side
I first unplugged the refirgerator. Note the time because the refrigerator should be unplugged at least 30 minutes before plugging back in (see end for why). A trouble light is necessary to see adequately. I removed the shelves and draws and put food in a picnic cooler. I took off the lower panel in the back of the freezer, and defrosted the coils with a hair dryer. I unplugged the wires to the defroster, and then the screw holding the coil to the back of the freezer side. I lifted up on the coil unit to clear the blade that inserts into the drain. I removed the bands on the top of the coil that hold the heating unit in place. I tilted the bottom out when there was clearance, and pulled the defrosting unit down and out. I replaced the new one, and reversed the procedure, and then plugged the wires back into the new defroster unit. The bands on the top should be secured before putting the coil back in place, as well as the foam spacers on top of coil, put the two wires back in the plastic clip that keeps them away from the fan and pipes. Replace lower freezer cover panel and screws. Put shelves and food back in. If at least 30 minutes have passed, plug the refrigerator back in. If you don't wait that long, their will still be pressure in the compressor and it will not start to cool properly right away. It works perfectly now. TIP: check the end of the drain hose periodically by taking off the lower back cover and pull th hose out - not hard to do. Mine plugged from dust and lint build up backing up into the end of the hose so water didn't drain out, and ice built up causing the defroster coil to burn out. I cut a little off the hose so the water level would not rise up into the hose, but the hose would still stay in place in the plastic holder.
Parts Used:
Defrost Heater
  • David from Chetek, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Odor like burning Electrical all through refrig.
Remove back panel inside Freezer compartment remove 2 screws that hold (small) fan motor. Unplug electric motor supply and install new motor in reverse order
Parts Used:
Evaporator Fan Motor
  • Gordon from Marlborough, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the LH guide rail on the drawer broke off
I slid upward and disengaged the front cover off the old drawer. Slid down the same front cover on the new one, slid the drawer in and it was like new again.

Initially i though this whole thing would take weeks, The website provided detailed exploded views, I ordered the part and it arrived in 2 days. It was too easy.
Parts Used:
Deli Drawer
  • Andrew from Jackson, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer kept icing over, refrigerator too hot
First, I unplugged the appliance. Safety, first.
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Parts Used:
Defrost Thermostat
  • debra from new washington, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Won't Auto Defrost
Make sure unplugged the frig before doing any repair. Just like other DIYers. opened up the evaporator located inside the freezer. Replaced the defrost thermostat, there's only 2 wires, so just make sure which is positive, which is negative. Replaced the defrost timer located on the bottom front of the frig. There's on 2 screws to unscrew. All those work took me less than half hour. Turn on the frig., now it works like a champ again. Hope it will last another 10 years.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Ricky from San Francisco, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fridge motor was running constantly and the fridge was warm inside
I secured the power to the fridge. I took the metal panel which covers the cooling coils in the freezer off by removing the the 6 sheet metal screws. I used a standard hair dryer to melt the ice block which had formed due to the failure of the defrost timer. I replace the defrost timer, which was located behind the left front wheel of the unit. Finding the timer was the hardest part of the job. Since I was having trouble with the defrost cycle I also decided to replace the defrost thermostat due to its age. The most important item I would like to share is once all the work is done and the panel is back in the freezer, the power is restored take a straight slot screw driver and give the defrost timer about an eighth of a turn clockwise to ensure it starts. Then mark it with a sharpe and check it in 3 or 4 hours to make sure it is running. I did not do this on the one I installed and the freezer did not go into the defrost cycle. Once I got the timer started, well the ice cream stay frozen. BE SURE NOT TO WORK ON YOUR EQUIPMENT WITH IT PLUGGED INTO POWER SOURCE!!!

Jim
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • James from Brighton, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace old water filter
The untwisted the water filter took out the old water filter and replaced it with the new one and twisted the cover back on. it was very easy to do and now the water tastes very fresh :) thank you
Parts Used:
Water Filter
  • Dung David from Phoenix, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was not making ice
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Parts Used:
Replacement Ice Maker
  • Jeffrey from Indianapolis, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condensor fan motor failed
Removed the old fan--three small nuts and snap off connection. Ordered part and received the next day. Your company is great!!
Parts Used:
Condenser Fan Motor Kit
  • Guy from Califon, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!