Fridge quit working.
A little research told me the hum plus no cooling was either the compressor or the relay. I ordered the new relay and put it in but it didn't fix the problem. I ended up having to buy a new fridge, but it was worth the $30 gamble to see if I could fix it on the cheap and it saved me the money a service call would've cost. Pretty easy installation, just in a tight space on my model.
Parts Used:
Run Capacitor
  • Bill from Bay City, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezing up
I damaged the timer while moving the fridge and did not realize it and it took 10 minutes to change out. "note" don't panic when it don't come immediately there is a dial in the front of the timer you can turn with a flat head screwdriver that will activate the timer
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Kenneth from ADGER, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
REFRIDGERATOR SECTION WANST GETTING COLD
freezer section remove ice trays ,shelves,unplug ice tray.use 1/4 nut driver remove back panel,use hair dryer thaw ice from evap coil ,unplug tstat remove install new one.plug in ice maker,put back panel back on ,ice maker and shelves plug refridgerator back in
Parts Used:
Defrost Thermostat
  • HAROLD from DETROIT, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer wasn't cooling - compressor not engaging
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other parts, but not happy that the actual part I needed was not available - had to use other methods.
Parts Used:
Run Capacitor
  • Judy from ROYSE CITY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original fan motor began masking a noise and finally stoped working.
Followed video instruction and completed the replacement. I had to join the wires since the connector was a male plug to a make plug.
Parts Used:
Evaporator Fan Motor Kit
  • Justin from FRANKLIN, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat , only cold air
After realizing the engineering on this dryer was different, I was able to access the temperature control thermostat through the front, along the side of the heating element. Several philips screws hold the front on, removing them allows you to take front panel off. At that point the heating element is below. I took a picture of the wires, so that when I started removing them, it would be easy to reconnect. Two screws hold the heating element in place, upon removing the heating element housing pulls gently forward and out, be careful of the wires, the thermostat is the second thing connected to the housing of the heating element. Two more philips screws hold the housing to the bottom of the dryer. Two wires are removed from thermostat, which is also held in place by two philips screws. Remove wires, one at a time and place on thermostat exactly as they were on old thermostat. Hold new thermostat in place with the two Philip screws, and reassemble in reverse order. And enjoy your working dryer once more, hopefully for years to come.
Parts Used:
Temperature Control Thermostat
  • Joseph from BUFORD, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator keeps running only turns off very seldomly
Problems. Two screws holding temperature control module to the plastic case did not fit the holes in temperature controler were too big. So I used gorilla glue to help secure but it was still loose a little bit with all the connections made i turned it on but it did not work
Parts Used:
Temperature Control Thermostat
  • Scott from Canton, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the copper refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Parts Used:
Run Capacitor
  • David from ABINGDON, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer was too warm. The fan was running: the diagnosis tool did not work!
I used the tool at Partselect that in theory allows diagnostic of the problem to be repaired. The result was that more tan 90% of the time with the introduced symptoms it had to be the thermostat. I order the part, got it quickly and installed. It did not fix the problem. So, be careful with the diagnostic tool, because it is just based on what most people buy when they have a particular problem. Videos for installation are great. If diagnosis was better, this would be fantastic. In my case there might be a different problem.
Parts Used:
Defrost Thermostat
  • Xavier from Philadelphia, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light bilb went out
replaced it
Parts Used:
Light Bulb
  • Denise from Landover, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My drawer rail broke off on the right side.
The process of repairing the draw was very simply. First I removed the broken part with a screw driver and simply slide the new part on and secured the part w/ a screw and that was it.
Parts Used:
Meat Drawer Hanging Rail - Right Side
  • STEFANIE from Killeen, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster didn't work
Ordered a new defroster timer and replace old one. It works just fine. A $35 repair vs a $500 new appliance.
Cool.
GWE
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Eatonville, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Sunnyvale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Meat drawer kept falling
I removed the screws from the old rail, which was broken, and installed the new rail using the old screws. It was very easy, and I wish I had fixed it months ago when it first broke.
Parts Used:
Meat Drawer Hanging Rail - Right Side
  • Thomas from Batavia, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refer iced up and would not keep the bottom cool. It was 70 Farenheit inside.
I simply removed 4 screws holding the casing and then 2 more holding the timer. It was very easy. I then replaced the timer by unplugging and plugged the new one in. I replaced all the screws and the job was done. Less than 30 minutes. I was very impressed with the shipping time. When I ordered the part, I had it the next day.
Parts Used:
Defrost Timer - 60Hz 120V
  • Larry from Newton, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!