Enter the code TAKE10OFF at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on May 28 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.