My fridge and freezer were not getting cold enough.
The Fridge and freezer were not very cold except for in the very back of the freezer (where the coils are). So I opened up the back of the freezer by first removing the dome light cover and removing all the visible screws. I then lifted up and pulled out the vent in the center of the back panel and removed the two remaining screws on the back panel. At that point I removed the back panel exposing the coils and fan. I saw that the fan was not spinning so I used a screw driver to manually turn the defrost timer found on the top of the inside of the fridge. Once I had turned the defrost timer once complete rotation, and the fan didn't turn on, I was pretty sure that it was the fan. I still wasn't sure that the fan was the only problem, but I couldnt see anything else that wasn't working properly. I decided to take a chance and order the fan motor (not the entire assembly. it is easy to replace the moter only leaving the original fan blades and housing). Once I got the part, I unplugged the old fan motor, put in the new fan motor, and pugged it in and it started spinning right away. I put everything back together the same way I took it apart and it has worked great ever since.
Parts Used:
Evaporator Fan Motor
  • Marcus from SLC, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Parts Used:
Ice Maker
  • GARY from PARRISH, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
34 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
Parts Used:
Defrost Timer - 120V 60Hz
  • Donald from worthington, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Parts Used:
Ice Maker
  • Gary from Glendale, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Parts Used:
Single Outlet Valve Kit
  • Raymond from Concord Twp., OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Parts Used:
Icemaker Switch
  • James from Mebane, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leak caused by earlier tube replacement destroying retaining washer in valve
This was a simple parts replacement. I had replaced the cracked plastic tube a few weeks earlier and destroyed the retaining star washer inside the solenoid valve while removing the old one. It worked for a while and then started to leak when the tube had partially worked its way out. The star washer is not a replaceable part so this repair was simply replacing the valve with a new one. It is very straight forward - disconnect the electric plug, remove the old valve, insert the tube in the new valve (it goes through the plastic bushing in the valve - do not remove the bushing - it can easily be mistaken for a shipping plug) and reattach the supply line being careful to avoid kinking it. Reattach the valve, the electric plug and support clips for both the supply line and the plactic line to the ice maker.
Parts Used:
TUBE PLASTIC CLAMP Single Outlet Valve Kit
  • George from Islamorada, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
18 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Parts Used:
Icemaker Stripper
  • Tracy from Yuba City, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the freezer worked but the refrigerator did not cool. The freezer iced up and did not defrost.
Replaced the defrost timer . It plugged in under the cover for the lights and controls in the refrigerator area. Replaced the deforst thermosat, took the rear cover off (at the back of the freezer) , cut the two wires and relaced the thermosat using wire nuts. Total repair time 30 minutes.
Parts Used:
Defrost Timer - 120V 60Hz Defrost Thermostat
  • erik from cut bank, MT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The frame had cracked
Just replaced it.
Parts Used:
Vegetable Pan Cover Frame - Glass NOT Included
  • Felicita from Elmwood Park, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Parts Used:
Ice Bucket - White
  • Tom from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Parts Used:
Single Outlet Valve Kit
  • Kenneth from Bellevue, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!