water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Parts Used:
Single Outlet Valve Kit
  • Raymond from Concord Twp., OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable)
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Parts Used:
Icemaker Switch
  • James from Mebane, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leak caused by earlier tube replacement destroying retaining washer in valve
This was a simple parts replacement. I had replaced the cracked plastic tube a few weeks earlier and destroyed the retaining star washer inside the solenoid valve while removing the old one. It worked for a while and then started to leak when the tube had partially worked its way out. The star washer is not a replaceable part so this repair was simply replacing the valve with a new one. It is very straight forward - disconnect the electric plug, remove the old valve, insert the tube in the new valve (it goes through the plastic bushing in the valve - do not remove the bushing - it can easily be mistaken for a shipping plug) and reattach the supply line being careful to avoid kinking it. Reattach the valve, the electric plug and support clips for both the supply line and the plactic line to the ice maker.
Parts Used:
TUBE PLASTIC CLAMP Single Outlet Valve Kit
  • George from Islamorada, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
18 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Parts Used:
Icemaker Stripper
  • Tracy from Yuba City, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The frame had cracked
Just replaced it.
Parts Used:
Vegetable Pan Cover Frame - Glass NOT Included
  • Felicita from Elmwood Park, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not work
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Parts Used:
Single Outlet Valve Kit
  • Kenneth from Bellevue, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice bucket missing
I discovered the ice bucket missing from my rental unit at the beach. I was able to go online with my Blackberry, easily navigate your website using the model number to look up the part information , order it, and have it in place for the next renter.
Without access to a friendly user website, I would have faced considerable delay in getting this part.
Parts Used:
Ice Bucket - White
  • Tom from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Parts Used:
Ice Maker
  • debbie from chino hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Parts Used:
Ice Maker
  • Barry from Phoenix, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator section not cold, freezer section cold
Based on the relatively young age of refrigerator, I suspected the defroster electrical circuit. The evaporator core in the freezer was frozen solid, which confirms that the defrost heater circuit is not working. Thawed out (with a hot air gun) and disassembled the freezer section to access the evaporator core and defrost heater. If you have an ice maker, you will have to remove it to disassemble the freezer section. Confirmed with a voltmeter and ammeter that the defrost heater was not getting voltage. When the defrost heater is working, it will glow with an orange color. Also confirmed with a voltmeter that the defrost timer, located in the refrigerator section was working correctly. You can use a common blade screwdriver to rotate the timer through the cold and defrost cycles. Finally, I determined with a voltmeter and ammeter that the defrost thermostat, located on the evaporator core was not switching the defrost heater voltage. Ordered a new thermostat ($12) from this website and installed it. Refrigerator is as good as new. Be careful, there are many electrical hazards during the troubleshooting phase. Safety first.
Parts Used:
Defrost Thermostat
  • David from Shalimar, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set, Wrench set
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Parts Used:
Ice Maker
  • Robert from Auburn, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 23 people found this instruction helpful.